USER MANUAL

Micromotor for oral surgery

01_26/04/2018

Page 1 of 15

USER MANUAL

DSI MICROMOTOR FOR ORAL SURGERY

0476

Summary of Contents for MINI SURGERY MOTOR

Page 1: ...USER MANUAL Micromotor for oral surgery 01_26 04 2018 Page 1 of 15 USER MANUAL DSI MICROMOTOR FOR ORAL SURGERY 0476...

Page 2: ...on the patients check the pre set operating parameters 8 Use only contra angles handpieces that conform with the essential requirements of European Directives and bear the CE mark as specified in the...

Page 3: ...while the operator risks electrocution If liquids are split on the equipment proceed as follows Shut off the equipment and unplug the power cord Immediately dry the equipment casing outside with a rag...

Page 4: ...1 Control unit 2 Micromotor with led 3 Variable speed pedal 4 Power supply cord 5 Micromotor support 6 Protective plug for sterilization 7 Bar for physiological solution Pic 2 Pic 3 1 Main switch 2 Po...

Page 5: ...e it for purposes other than those it is specifically designed for Do not place the equipment near direct or indirect sources of heat Do not put the equipment in humid environments or in contact with...

Page 6: ...rol unit Assembly the handpiece contra angle or straight on the micromotor and insert the micromotor into the support Use only handpieces with E Type connection ISO 3964 that comply as medical devices...

Page 7: ...of control unit Connect the power supply cord to a grounded socket Switch on the device by the main switch USE All the adjustments are to be made with the motor stopped The display shows the followin...

Page 8: ...lay Key 5 Led activation Switch on off the led when led is turned on the symbol is highlighted If pressed for 2 seconds key n 5 activates deactivates motor led function this function automatically swi...

Page 9: ...ION AND STERILIZATION WARNINGS The operators performing the cleaning and sterilization operations must be adequately protected and trained Limitations to Repeated Processes Repetition of processes has...

Page 10: ...special requirements Packaging Insert the protective cap on the micromotor The micromotor can be sterilized see instructions below only if provided with the protective cap accessory supplied List of...

Page 11: ...ective The DSI Mini Surgery Motor device must function in the electro magnetic field specified below The customer user of DSI Mini Surgery Motor must guarantee that it is used in this environment DSI...

Page 12: ...es continued operation during power mains interruption it is recommended that the product be powered from a separate power supply UPS etc Magnetic field at network frequency 50 Hz 3 A m 3 A m Magnetic...

Page 13: ...s must be less than 3 V m DSI Mini Surgery Motor is intended for use in an electromagnetic environment in which radiated radiofrequency disturbances are controlled The DSI Mini Surgery Motor user and...

Page 14: ...cycling treatment and compatible environmental disposal helps to avoid possible negative effects on the environment and health and favors the re use and or recycling of the materials it is composed of...

Page 15: ...and ss mm ii Follow the instructions for use Attention carefully read the user manual before use It is afraid of humidity RAEE appliance separate collection object BF type electro medical device Fragi...

Reviews: