background image

 
 

 

 

VG7000 Digital Gateway allows DSG IP-PBX to connect with ISDN and TCP/IP network and adopt E1 or T1 trunk 
services. VG7000 needs to be installed in clean, dry, adequately ventilated areas. Please always use ESD-preventive 
tools when you plug or unplug the power cord. 
 

Packaging Contents 

y

 

VG7000 Digital Gateway

 

y

 

RS232 Cable 

y

 

DSG CD 

y

 

Power Cord 

 

The default IP settings of VG7000 are as follows. You might need to change its IP address to conform to your 
network requirement. 

y

 

Default IP: 192.168.1.202:89 (Service Port: 89) 

y

 

Default Subnet Mask: 255.255.0.0 

y

 

Default Gateway: 192.168.0.254 

y

 

Default Password: 1234 

 

Settings on InterServer: Add License Key and Digital Gateway 

1.

 

Select a PC which is able to connect to InterServer. Launch the web browser and on the address bar, input 
your InterServer’s IP address (the service port is 88) to access your IP-PBX system. 

2.

 

Click the Administrator icon and then login with your user name and password. 

3.

 

Be sure you have the appropriate License Key. Go to Main Menu>Operation Management>General 
Information. Click the Add button to set your License. 

4.

 

Go to Main Menu>Gateway Configuration>Digital Line Gateway. Click Add to increase a Digital Gateway. 

 

y

 

Name

: Enter a name to describe this Digital Gateway. 

y

 

MAC Address:

 Enter the MAC address of the Digital Gateway. You may find it from the device label. 

y

 

Trunk Number

: Enter the available trunk numbers you may use or purchase. 

y

 

CO Line per Trunk

: Input the available channels of each trunk. For example, input 32 for E1 or 24 for T1. 

y

 

CO Line Extension Base: 

Input the starting number of CO Line extension number. The CO Line extension 

numbers will be assigned automatically. For example if you set “4000” for an E1 port, the associated 
extension numbers will be 4000-4031. 

y

 

Jitter Buffer

: From “Jitter Buffer Depth” drop down menu, depending on your bandwidth and CODEC, 

start with a Jitter Buffer with the minimum value. 

y

 

Off-Premises and IP address:

 For Off-Premises Gateways, you will need to select the check box and enter 

its “IP Address”. A real (public) IP address is required for Off-Premises Gateways.   

y

 

QoS:

 If your network supports QoS, click the check box to activate this function. 

 

Installing VG7000 Digital Gateway 

 

Link  
TX/RX 
Ready

 

Lit: Connected to LAN 
Flashing: Activity 
Lit: Connected to PBX Server 

Sync 

Green: Physical layer sync ready 
Flashing Red: Acquiring 
Red: Alarm 

D-Link 

Green: Sync with Data Channel 
Flashing Green: Acquiring 
Red: Initial failed 

 

 

VG7000 Digital Gateway Quick Installation Guide 