INSTALLATION
TIMER
FIND IT
Settings
Installation
Timer
Setting
Default
Description
Normal Entry-
Exit Delay
Entry: 30
Exit: 60
Entry Delay:
How much time users have to enter their code after opening a
door programmed as an Normal Entry/Exit delay door
When SIA Limits enabled: 30 to 240 seconds
When SIA Limits disabled: 05 to 240 seconds
Exit Delay:
How much time users have to exit the location before the panel
arms itself.
When SIA Limits enabled: 45 to 254 seconds
When SIA Limits disabled: 05 to 254 seconds
Long Entry-Exit
Delay
Entry:
100
Exit: 120
Change entry and exit delay lengths in the “Timer” app.
Installer Code Access
Master Code Access
DSC Confidential and Proprietary Page of
54 114
© Last updated 4/29/15 All rights reserved
Note: For UL/cUL, set the entry delay to 45 sec.and exit delay max 120 sec. for UL and max 60 sec. for cUL.