DSC PC5720 Installation Manual Download Page 1

Installation

Manual

PC572O

SUR-GARD  V2.2

1-8OO-387-363O

© 1998 Digital Security Controls Ltd.

1645 Flint Road, Downsview, Ontario, Canada M3J 2J6

Printed in Canada     29003276 R0

W   A  R   N   I  N   G  –

 This manual contains information on

limitations regarding product use and function and information
on the limitations as to liability of the manufacturer. The entire
manual should be carefully read.

Summary of Contents for PC5720

Page 1: ...1645 Flint Road Downsview Ontario Canada M3J 2J6 Printed in Canada 29003276 R0 W A R N I N G This manual contains information on limitations regarding product use and function and information on the...

Page 2: ...w Battery Reporting Codes 11 13 Miscellaneous Option Reporting Codes 11 20 Handheld Keypad Low Battery Reporting Types 11 21 Wireless Key 1 8 Low Battery Reporting Types 11 22 Wireless Key 9 16 Low Ba...

Page 3: ...orting Types 18 71 Zone 17 24 Alarm Restore Bypass Reporting Types 18 72 Zone 25 32 Alarm Restore Bypass Reporting Types 18 73 Zone 1 8 Tamper Restore Reporting Types 18 74 Zone 9 16 Tamper Restore Re...

Page 4: ...0mA standby 100mA with printer 120mA with F1 F2 L3 Tamper and Trouble reporting codes Maximum cable length 200 feet 61 meters Eight zone inputs one ground fault detection zone two normally open Class...

Page 5: ...vely Refer to your panel s Installation Manual for complete instructions on Keybus wiring Zone Input terminals The zone inputs Z10 to Z14 as well as A and B will report as PC5010 zones 10 16 This is n...

Page 6: ...expanders 1 and 2 zones 9 12 zones 13 16 These three areas of supervision correspond to supervision zone lights 20 printer or 22 alternate communicator 9 and 10 when all modules are displayed by enter...

Page 7: ...6 PC5720 Wiring Diagram...

Page 8: ...ormation will be transmitted from the PC5720 module to the serial printer There are four different baud rates available If you are experiencing problems with missing characters try lowering the baud r...

Page 9: ...ll call 01 response on all call 1 only 02 response on all call 2 only 03 response on both all calls 04 modules with odd numbered ID codes see section 40 respond to All Call 1 Modules with even numbere...

Page 10: ...that zone 1 is a fire zone Refer to the DVACS Reporting Type tables on pages 24 27 To have the PC5720 transmit a pre programmed code from the internal table leave the programming at the default value...

Page 11: ...al Printer enabled DVACS enabled OFF I____I Option 2 8 For future use PC5010 and PC5015 Programming Sections If you will be connecting the PC5720 to a PC5010 or PC5015 control panel access the PC5720...

Page 12: ...ting Types Default Default FF I____I____I Handheld Keypad 1 FF I____I____I For future use FF I____I____I Handheld Keypad 2 FF I____I____I For future use FF I____I____I Handheld Keypad 3 FF I____I____I...

Page 13: ...16 16 16 16 24 Hour Panic 26 26 26 26 26 24 Hour Non Alarm 07 07 07 07 07 Delayed 24 Hour Fire Hardwired 17 17 17 17 17 24 Hour Emergency 87 87 87 87 87 Delayed 24 Hour Fire Wireless 08 08 08 08 08 St...

Page 14: ...o All Call 2 E g a module withID code 03 will respond to All Call 1 A module with ID code 04 will respond to All Call 2 42 Miscellaneous Options Default Option ON Option OFF ON I____I Option 1 All Cal...

Page 15: ...wnlook Module Supv Restore FF I____I____I PC5400 Supv Fault Rest FF I____I____I PC5132 Supervisory Fault Restore FF I____I____I Alt Comm LINKS SupvFlt Rest FF I____I____I PC5208 Supervisory Fault Rest...

Page 16: ...FF I____I____I Zone 26 FF I____I____I Zone 30 FF I____I____I Zone 27 FF I____I____I Zone 31 FF I____I____I Zone 28 FF I____I____I Zone 32 53 Zone 1 8 Tamper Restore Reporting Codes Default Default FF...

Page 17: ...e 10 FF I____I____I Zone 14 FF I____I____I Zone 11 FF I____I____I Zone 15 FF I____I____I Zone 12 FF I____I____I Zone 16 59 Zone 17 24 Trouble Restore Reporting Codes Default Default FF I____I____I Zon...

Page 18: ...30 FF I____I____I Zone 27 FF I____I____I Zone 31 FF I____I____I Zone 28 FF I____I____I Zone 32 65 Keypad Tamper Restore Reporting Codes Default Default FF I____I____I Keypad 1 FF I____I____I Keypad 5...

Page 19: ...____I____I Zone 9 FF I____I____I Zone 13 FF I____I____I Zone 10 FF I____I____I Zone 14 FF I____I____I Zone 11 FF I____I____I Zone 15 FF I____I____I Zone 12 FF I____I____I Zone 16 71 Zone 17 24 Alarm R...

Page 20: ...__I Zone 26 FF I____I____I Zone 30 FF I____I____I Zone 27 FF I____I____I Zone 31 FF I____I____I Zone 28 FF I____I____I Zone 32 77 Zone 1 8 Trouble Restore Reporting Types Default Default FF I____I____...

Page 21: ...FF I____I____I Zone 14 FF I____I____I Zone 11 FF I____I____I Zone 15 FF I____I____I Zone 12 FF I____I____I Zone 16 83 Zone 17 24 Low Battery Restore Reporting Types Default Default FF I____I____I Zon...

Page 22: ...xpander Module 89 First DVACS Reporting Types Default Default FF I____I____I Duress Alarm FF I____I____I PGM2 Input Alarm Restore FF I____I____I Keypad F Key Alarm Restore FF I____I____I PC5132 Tamper...

Page 23: ...ifth DVACS Reporting Types Default Default FF I____I____I ESCORT 5580 Supv Fault Restore FF I____I____I System Test FF I____I____I Keypad Lockout FF I____I____I Installer Lead In Lead Out FF I____I___...

Page 24: ...A WH WB WU 000 999 0E Freeze Alm Rst Byp Unb Zn000 999 ZA ZH ZB ZU 000 999 0F Gas Alm Rst Byp Unb Zn000 999 GA GH GB GU 000 999 10 Heat Alm Rst Byp Unb Zn000 999 KA KH KB KU 000 999 11 24 hrs Alm Rst...

Page 25: ...eeze Trb T_R Byp Unb Zn000 999 ZT ZJ ZB ZU 000 999 2F Gas Trb T_R Byp Unb Zn000 999 GT GJ GB GU 000 999 30 Heat Trb T_R Byp Unb Zn000 999 KT KJ KB KU 000 999 31 24 hrs Trb T_R Byp Unb Zn000 999 UT UJ...

Page 26: ...C Motion Sup S_R Byp Unb Zn000 999 BS BJ BB BU 000 999 6D Water Sup S_R Byp Unb Zn000 999 WS WJ WB WU 000 999 6E Freeze Sup S_R Byp Unb Zn000 999 ZS ZJ ZB ZU 000 999 6F Gas Sup S_R Byp Unb Zn000 999 G...

Page 27: ...1B Fire test begin FI 1C Fire test end FK 1D User cd Tamper JA 1E Log Threshold JL 1F Log Overflow JO 20 Schedul Execute JR 21 Schedul Change JS 22 Time Changed JT Rep Code Printer MSG Computer MSG 23...

Page 28: ...y 05 85 QA0zz QH0zz 24 Hr Sprinkler 01 81 SA0zz SH0zz 24 Hr Water 0D 8D WA0zz WH0zz 24 Hr Freeze 0E 8E ZA0zz ZH0zz 24 Hr Latching Tamper 16 96 TA0zz TR0zz Interior Delay 08 88 BA0zz BH0zz Duress 03 99...

Page 29: ...zz 24 Hr Panic 62 E2 PS0zz PJ0zz 24 Hr Emergency 65 E5 QS0zz QJ0zz 24 Hr Sprinkler 61 E1 SS0zz SJ0zz 24 Hr Water 6D ED WS0zz WJ0zz 24 Hr Freeze 6E EE ZS0zz ZJ0zz 24 Hr Latching Tamper 71 F1 US0zz UJ0z...

Page 30: ...m Rst 20 A0 00 FT000 FJ000 Aux Power Alm Rst 3C BC 01 YP001 YQ001 TLM Alm Rst Links 3E BE 00 LT000 LR000 Phone 1 Alm Rst 3E BE 01 LT001 LR001 Phone 2 Alm Rst 3E BE 02 LT002 LR002 Keybus Fault Alm Rst...

Page 31: ...CL046 Automatic Closing 7E 01 CA MISCELLANEOUS SYSTEM REPORTS Event Description MT Function Byte Low Zone SIA Message Keypad Lockout 7E 1D JA Remote ESCORT Access 7E 16 DO DLS Lead In Lead Out 7E 2F...

Page 32: ...not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detec...

Page 33: ...ich may be revised from time to time will be charged for each unit repaired Products which Digital Security Controls Ltd determines not to be repairable will be replaced by the nearest equivalent prod...

Page 34: ...1645 Flint Road Downsview Ontario Canada M3J 2J6 Printed in Canada 29003276 R0 W A R N I N G This manual contains information on limitations regarding product use and function and information on the...