DSC gs3055-i cf Installation Manual Download Page 1

GS3055-I

GSM-GPRS INTERFACE

WARNING

This manual contains information on limitations regarding product use and function

and information on the limitations as to liability of the manufacturer.

INSTALLATION MANUAL

Summary of Contents for gs3055-i cf

Page 1: ...55 I GSM GPRS INTERFACE WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer INSTALLATION MANUAL ...

Page 2: ... INSTALLINGTHE GS3055 I 4 CONNECTINGTHE GS3055 I 4 STATUS LEDS 5 OPERATING PRINCIPLES 6 Simulated Land Line Mode 6 Sequence 6 Inputs 6 ACTIVATINGTHE OUTPUTS 7 Activating the Outputs 7 Contact ID 7 Events Description 7 Event Codes 7 C 24 REMOTE PROGRAMMING 7 APPENDIX 8 INSTALLATION MANUAL 10 GS3055 I GSM GPRS INTERFACE 10 ...

Page 3: ...ent 80mA Alarm Transmitting current 450mA PGM outputs 4 open collector rated 50mA Operating frequency 850 1900MHz Antenna Gain 1 5dB Environmental specifications Environmental specifications Environmental specifications Environmental specifications Environmental specifications Operating temperature 0 49C 32F 120F Humidity 93 RH Mechanical specifications Mechanical specifications Mechanical specifi...

Page 4: ...stallations for supplementar NOTE The GS3055 I is listed for UL installations for supplementar NOTE The GS3055 I is listed for UL installations for supplementar NOTE The GS3055 I is listed for UL installations for supplementary use only y use only y use only y use only y use only The performance of the GS3055 I depends greatly on GSM Network coverage therefore it should not be mounted without firs...

Page 5: ...for the bat tery leads which are not power limited Do not route any wiring over circuit boards Maintain at least 1 25 4mm separation A minimum 1 4 6 4mm separation must be maintained at all points between Power Limited wiring and all other Non Power Limited wiring Route wires as indicated in the diagram N PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Metal Casing GSM Antenna GSM Antenna Nuts ...

Page 6: ...card please ensure the unit is powered down 5 Power up the GS3055 I and check signal strength Connect battery to the RED and BLK battery leads Connect DC Power source to 12V terminals Allow unit to power up The green LEDs will indicate the signal strength The bottom green LED must be ON for the location to be acceptable Please refer to the Status LEDs section for more information 6 Power down the ...

Page 7: ...Inputs section for details 12V 19 COM 20 Device Power Supply 12V 19 COM 20 Device Power Supply 12V 19 COM 20 Device Power Supply 12V 19 COM 20 Device Power Supply 12V 19 COM 20 Device Power Supply These terminals must be connected to a rated power supply Once the connections are completed connect the Red and Black wires 13 13 13 13 13 to a 12V 1 2Ah battery Jumper 3 Jumper 3 Jumper 3 Jumper 3 Jump...

Page 8: ...the land line is still down if the land line is still down if the land line is still down it will continue to simulate the land line until it is restored The GS3055 I will not switch during ongoing calls Sequence When alarm is triggered the Alarm Panel goes off hook The GS3055 I will assert dial tone Control Panel dials the number of the central station Ensure the alarm panel inserts a minimum 1 s...

Page 9: ...l Module T OUTPUT 4 General Module T OUTPUT 4 General Module Tr r r r rouble ouble ouble ouble ouble Output is normally low and will switch to high when any of the previous troubles occur and or a Failure to Communicate FTC trouble is detected NOTE Once an output has been activated automatically it will not restore its state until all the causes of activation are cleared Contact ID Events Descript...

Page 10: ...er Interface Supports Contact ID format External Power Supply Telephone Line Connection RM 1 Relay WARNING Incorrect connections may result in PTC failure or improper operation Inspect wiring and ensure connections are correct before applying power Connect relay contacts to a zone input on the alarm control panel for GS3055 I troubles supervision 24h type zone optional use of PGM output See Progra...

Page 11: ......

Page 12: ...ity If trouble is experienced with this equipment for repair or warranty information please contact the facility indicated below If the equipment is causing harm to the telephone network the Telephone Company may request that you disconnect the equipment until the problem is solved This equipment is of a type that is not intended to be repaired by the end user DSC c o APL Logistics 757 Douglas Hil...