Identification of Parts
Figure 1: Parts
PS4085
12+V COM ACT LBT TEST
AC IN
CON1
12V/7Ah
Model DSC BD12-7
Cable Tie
A
B
C
AC IN
120 VAC
60 Hz
0.3A
Cable Tie (not provided)
To prevent wires from falling onto batteries,
secure them to the enclosure or to the plastic
stand-off.
All circuits are Power Limited
except AC and Battery
Power
Limited
Power
Limited
Power
Limited
Non-Power
Limited
10
11
12
13
2
9
14
1
INSTALL BATTERY & AC WIRING AS SHOWN
IMPORTANT!:
All circuits are classified for
UL installations as Power Limited/Class II
Power Limited except for the battery leads
and primary AC wiring which are not power
limited. Do not route any wiring over circuit
boards. Maintain at least 1” (25.4mm)
separation. A minimum 1/4” (6.4mm)
separation must be maintained at all points
between Power Limited wiring and all other
Non-Power Limited wiring. Route wires as
indicated in the diagram.
For UL/ULC Commercial Fire Installations,
connections between the fire alarm control
panel inputs/outputs (telephone interface
Tip/Ring or output relay contacts) and
3G4010CF inputs/outputs (T1/R1, Z1-Z4,
PGM1-4) shall be run in a mechanical
protective conduit within 20ft(UL)/18m(ULC)
and in the same room.
+BAT -BAT
WARNING!: HIGH VOLTAGE
DISCONNECT POWER AND TELEPHONE
LINES PRIOR TO SERVICING
4
3
6
5
15
7
8
C ON3
LE D2
B
A
T
+
O
P
E
N
+
LE D1
B
A
T
-
-
LE D4
LE D3
UA673
S
E
R
IA
L
N
U
M
B
E
R
EGND
Part
1
3G Antenna
2
Metal Casing
3
Antenna Mounting Hardware
4
Antenna Connector
5
Anchor Screw Holes (3mm)
6
SIM Card Holder
7
3G (HSPA) Radio Module
8
Status LEDs (See page 1)
Part
9
PC-Link Connector
10
Tamper Switch
11
Terminal Blocks
12
Battery Leads
13
Cable Entry
14
Earth Ground Wire
15
12V Battery
NOTE:
Connection of metal-clad cable, conduit, metal raceway or the like is permitted as a means for grounding. Use the sup-
plied star-washers to secure the mains connection box cover and the front cover of the enclosure.
NOTE:
All circuits are classified for UL installations as Power Limited/Class II Power Limited except for the battery leads which
are not power limited. Do not route any wiring over circuit boards. Maintain at least 1” (25.4mm) separation. A minimum 1/4”
(6.4mm) of separation must be maintained at all points between Power Limited wiring and all other non-Power Limited wiring.
Route wires as indicated above.
This equipment 3G4010CF is fixed and shall be installed by Service Persons only (Service Person is defined as a person hav-
ing the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed
in performing a task, and of measures available to minimize the risks to that person or other persons). It shall be installed and
used within an environment that provides the pollution degree max 2, over voltages category II, in non-hazardous, indoor loc-
ations only. This manual shall be used with the Installation Manual of the relevant alarm control panel. All instructions specified
within that manual must be observed.
5