5. SAFETY
5.1 General
3
- Observe the generally applicable regulations and precautions/safety instructions in this manual.
- Read this manual carefully to ensure the proper and safe installation of the appliance.
- Prior to starting the installation, check that the correct appliance has been delivered on the basis of table 4-1.
5.2 Regulations
Please install the appliance in accordance with the applicable national, local and constructional (installation) regulations.
5.3 Safety instructions
3
Carefully observe the following precautions/safety instructions:
- Installation and maintenance of the appliance should be performed by an installer.
- The appliance was designed for atmospheric and heating purposes. This means that all visible surfaces, including the
glass pane, can become hotter than 100°C. It is recommended to always place a guard grille in front of the appliance
when children, older people or persons with reduced physical, sensory or mental capacities are in the same room as
the appliance. If these vulnerable people are regularly present in the room without supervision, a fixed guard should
be made around the appliance.
- Keep combustible objects and/or materials outside the appliance's radiation range (see section 7).
- Do not cover the appliance and/or do not wrap it in an insulation blanket or any other material.
- Do not use the appliance when a pane is broken and/or cracked, until it has been replaced.
- Only use the flue gas discharge / combustion air supply system (concentric system) supplied by DRU.
3
When installing the appliance, heed the following warnings:
- Do not make any changes to the appliance.
- Only use the accompanying set, such as the wood or pebble set, and place it exactly as described.
- Leave space around the ionisation pin and spark electrode and never place glow material around these pins.
- Place a gas tap in accordance with applicable regulations.
- Make sure there is no dirt in gas pipes and connections.
- Check the complete installation for gas tightness prior to commissioning.
- Do not ignite the appliance until it is fully installed in relation to the gas connections, discharge system and electrical
components.
3
When installing a built-in appliance:
- Prevent the explosion hatch(es) on the top of the appliance (if present) from getting clogged and check that they
properly fit on the sealing surface, before the appliance is built in.
- Use non combustible and heat-resistant materials for the chimney breast, including the top of the chimney breast and
the material in the chimney breast, such as the floor under the appliance and the back wall against which the appliance
will be placed. For this you can use both special sheet material and stone-like materials.
- Take sufficient measures to prevent excessive temperatures of a wall behind the chimney breast, including the
materials and/or objects behind the wall.
- Take the minimum required internal dimensions of the chimney breast into account. These are for the benefit of safety
and for the prevention of excess heat accumulation in the chimney breast.
- Ventilate the chimney breast by means of ventilation holes (see section 7). These are essential for safety and for the
prevention of excess heat accumulation in the chimney breast.
- Use heat resistant electrical connectors.
- Place heat-resistant electrical wiring away from the appliance and as low as possible in the chimney breast. This has to
do with the temperature development in the chimney breast.
3
When installing a free-standing appliance:
- Place the appliance at the indicated minimum distance from the back wall and side walls (see section 7).
I nst allation manual
7
Summary of Contents for Maestro 60/2 Tall RCH
Page 15: ...Installation manual 15 A D B C 38C 2500 7 4...
Page 17: ...Installation manual 17 1 3 4 2 38C 2504 tooltip tooltip 7 6...
Page 19: ...Installation manual 19 38C 2793 1 2 3 4 5 6 7 7...
Page 21: ...Installation manual 21 1 3 2 4 38C 2619 586 5mm 1 2 38C 2503 7 8 7 9...
Page 23: ...Installation manual 23 5 7 8 6 38C 2507 1 60 1 3 2 4 2 mm 38C 2506 1 7 10 7 11...
Page 24: ...Installation manual 24...
Page 29: ...Installation manual 29...
Page 32: ...Installation manual 32...
Page 37: ...Installation manual 37 1 2 3 4 5 6 7 8 9 12 11 10 38C 2511 2 7 15...
Page 47: ...Installation manual 47 38P 0820 2 8 16...
Page 48: ...Installation manual 48 38P 0815 2 Eco Glow 38P 0814 2 Eco Glow 8 17 8 18...
Page 49: ...Installation manual 49 A C 38P 0816 2 B 8 19...
Page 50: ...Installation manual 50 D E 38P 0817 2 1 cm 8 20...
Page 51: ...Installation manual 51 38P 0819 0 Eco Glow F 38P 0818 0 G Eco Glow 8 21 8 22...
Page 52: ...Installation manual 52...
Page 57: ...Installation manual 57...
Page 64: ...Installation manual 64...
Page 65: ...Installation manual 65...
Page 66: ...Installation manual 66...
Page 67: ...Installation manual 67...