10
3.5 Standard pump components
STANDARD PUMP COMPONENTS
1
Laser minimum level
7
Pumping system
2
Maximum level
8
Bypass
3
Reservoir
9
Pressure gauge
4
Ratio motor
10
Filling (for grease pump)
5
Delivery line 1
11
Reservoir minimum level (for oil pump)
6
Delivery line 2
12
Lubricant filler cap (for oil pump)
3.5.1 Inverters
For the inverter technical specifications and the methods of use, see the specific product manuals attached to the pump.
3.5.2 Fixed fixed flow rate pump elements
The pump is configured with one or two fixed flow rate pumping elements (110 cm^3/ min for each pumping element).
The seal between piston and pumping body is a dry type since it has no gasket in between.
The pumping element check valve is the tapered seal type. This solution allows an outstanding seal of the system to be
guaranteed at high operating pressures (max pressure of 400 bar – 5800 psi).
The pumping elements are mounted on the pump body without the need to disconnect the piping of the line with a
threaded connection, which makes it easy to assemble/disassemble.
9
8
1
2
4
5
3
10
7
12
11
Return
Delivery
Detail without