9.2.

 

SCHEDULED MAINTENANCE 

The following table lists the periodic inspections, the frequency and the intervention that the maintenance will have to carry 
out in order to ensure the efficiency of the system over time. 
 

CHECK 

FREQUENCY 

INTERVAL 

INTERVENTION 

Attachment of the lines. 

After  the  first  500 
hours of operation 
Every  1500  hours  of 
operation. 

Check the joint fittings. 
Check the fastening to the parts of the machine. 

Reservoir level. 

As required. 

Fill the reservoir with clean lubricant; 

Clogging of the filling filter. 

400 work cycles. 

Disassemble and clean the filter. 

Clogging of the return filter (where applicable). 

400 work cycles. 

Disassemble and clean the filter. 

Presence  of  deposits  on  the  bottom  of  the 
reservoir. 

600 work cycles. 

Clean the reservoir. 

10.

 

DISPOSAL 

Do not dispose of polluting components in the environment during pump maintenance or in case of demolition; refer to local 
regulations  for  correct  disposal.  Upon  demolition  of  the  pump,  the  identification  label  and  any  other  document  must  be 
destroyed. 

11.

 

ORDER INFORMATION 

Version WITH RESERVOIR for GREASE 

Part number 

Command 

Grease 

Characteristics 

3414008 

Single acting 

NLGI 2 

With grease-pusher disc and spring (2kg reservoir). 

3414012 

NLGI 1 

With grease-pusher disc and MIN level electrical contact. 

3414050 

NLGI 2 

With grease-pusher disc and MIN level electrical contact. 

3414022 

NLGI 2 

With grease-pusher disc and spring. 

3414014 

Dual acting 

NLGI 1 

With grease-pusher disc. 

Version WITHOUT RESERVOIR for OIL 

Part number 

Command 

Characteristics 

3414004 

Single acting 

Special reservoir applications. 

3414009 

For pumps P/N: 

3414008; 3414012; 3414022; 3414050.

 

3414007 

Dual acting 

Special reservoir applications. 

3414017 

For dual acting pumps P/N: 

3414014.

 

 

OPTIONAL KITS and ACCESSORIES 

Part number 

Voltage and 
frequency 

Characteristics 

0044307 

110V/50Hz 

4-way solenoid valve for pumps P/N: 

3414004; 3414008; 3414012; 3414022; 3414050.

 

0044450 

220V/50Hz 

0044306 

24V/50Hz 

0044310 

110V/50Hz 

4-way solenoid valve for pumps P/N: 

3414007; 3414014.

 

0044311 

220V/50Hz 

0044309 

24V/50Hz 

 

 

Summary of Contents for 3414 Series

Page 1: ...nches and authorised distributors Go to www dropsa com or write to sales dropsa com C2014IE WK 14 19 1 INTRODUCTION 2 GENERAL DESCRIPTION 3 PRODUCT IDENTIFICATION 4 TECHNICAL CHARACTERISTI 5 COMPONENT...

Page 2: ...out reservoir for applications on special reservoirs or reservoirs owned by the customer Fitted with plate with holes for lubricant entry with G UNI ISO 228 1 threading 3 PRODUCT IDENTIFICATION A yell...

Page 3: ...DUAL ACTING VERSION WITH RESERVOIR Fixing bracket Identifying tag ELECTRIC Minimum level Reservoir fill inlet G Lubricant outlet Rp Dual acting inlet outlet G Control cylinder Reservoir Level check d...

Page 4: ...al posture or possible impact Do not install the pump submerged in liquids and or in aggressive environments Do not install the pump in environments where there are explosive or flammable mixtures Ens...

Page 5: ...ype of lubricant Depending on these variables to achieve a proper supply to the delivery point it is always necessary to ensure that the pipeline pressure loss plus the pressure required at the lubric...

Page 6: ...tighten all the fittings ensuring that there are no leaks The piston of the pumping element is worn out Replace the piston The delivery valve is blocked Replace the valve The pump does not dispense lu...

Page 7: ...t disposal Upon demolition of the pump the identification label and any other document must be destroyed 11 ORDER INFORMATION Version WITH RESERVOIR for GREASE Part number Command Grease Characteristi...

Page 8: ...050 523 20 6 736 28 97 196 7 7 280 11 02 75 2 95 3414022 511 20 1 661 26 02 192 3 5 276 10 86 75 2 95 3414014 Dual acting 511 20 1 761 29 9 192 3 5 276 10 86 75 2 95 Version WITHOUT RESERVOIR for OIL...

Page 9: ...NBR gasket compatible lubricants Any residual lubricant inside that was used for assembly and testing is NLGI 0 grade 15 CONTRAINDICATIONS OF USE Compliance with the essential safety requirements and...

Reviews: