background image

1.

 

INTRODUCTION 

This operation and maintenance manual refers to the 

Hydraulically controlled pump - Series 3414...

 and contains important 

information for the health and safety protection of the personnel who use this equipment. 
The most recent version can be obtained by requesting it from the Sales Technical Office or online at 

http://www.dropsa.com

. 

 
This manual must be read carefully and kept so that it is always available to the operators who want to consult it. 

2.

 

GENERAL DESCRIPTION 

The 

Hydraulically controlled pump - Series 34

14…

, of sturdy construction and highly reliable, is made up of a galvanized steel 

body, piston in hardened and lapped steel and a hydraulic control cylinder in which a piston slides with anti-oil rubber gasket. 
The control requires a 4-way solenoid valve (line - cylinder - discharge) for dual action pumps. The solenoid valve can also be 
used 3 ways (plugging one of the outlets) for single acting pumps. The solenoid valve is supplied on request by Dropsa Spa. 
It can also come with an electrical contact for the minimum level check. 
The pump can be supplied without reservoir for applications on special reservoirs or reservoirs owned by the customer. Fitted 
with plate with holes for lubricant entry with G½ UNI-ISO 228/1 threading. 

3.

 

PRODUCT IDENTIFICATION 

A yellow is located on the front part of the pump that indicates the product code and the basic characteristics. 

4.

 

TECHNICAL CHARACTERISTICS 

GENERAL TECHNICAL CHARACTERISTICS 

CHARACTERISTIC 

U.M. 

VALUE 

Operating temperature 

°C - [°F] 

-5 

÷

 +80 - [+23 

÷

 +176] 

Storage temperature 

°C - [°F] 

-20 

÷

 +50 - [-4 

÷

 +122] 

Operating relative humidity 

90 

Flow rate 

cm³/stroke 

[cu.in./stroke] 

0.5 

÷

 2 

[0.17 

÷

 0.31] 

Filling filter 

Type 

Metallic 

Sound pressure level 

dB(A) 

<70 

Lubricant outlet 

Thread 

Rp ¼ UNI-ISO 

  7/1 

Control oil inlet 

Thread 

G ¼ UNI ISO 

 228/1 

Control oil viscosity 

cSt - [SUS] 

15 

÷

 100 - [77.31 

÷

 462.6] 

Version WITH RESERVOIR for GREASE 

Reservoir capacity 

kg - [lb] 

÷

 5 - [4.4 

÷

 11.2] 

Lubricant grade 

NLGI 

÷

 2 

Reservoir filling 

Thread 

G ½ UNI ISO 

 228/1 

Version WITHOUT RESERVOIR for OIL 

Lubricant oil viscosity 

cSt - [SUS] 

15 

÷

 2000 - [77.31 

÷

 9256] 

Lubricant inlet 

Thread 

G ½ UNI ISO 

 228/1 

SINGLE ACTING versions 

Compression ratio 

4.8:1 

Control oil pressure 

bar - [psi] 

30 

÷

 60 - [441 

÷

 882] 

DUAL ACTING versions 

Compression ratio 

1:1 

Control oil pressure 

bar - [psi] 

30 

÷

 150 - [441 

÷

 2205] 

 

 

ATTENTION: Do not power the machine with pressure different than what is indicated on the label. 

 

 

Summary of Contents for 3414 Series

Page 1: ...nches and authorised distributors Go to www dropsa com or write to sales dropsa com C2014IE WK 14 19 1 INTRODUCTION 2 GENERAL DESCRIPTION 3 PRODUCT IDENTIFICATION 4 TECHNICAL CHARACTERISTI 5 COMPONENT...

Page 2: ...out reservoir for applications on special reservoirs or reservoirs owned by the customer Fitted with plate with holes for lubricant entry with G UNI ISO 228 1 threading 3 PRODUCT IDENTIFICATION A yell...

Page 3: ...DUAL ACTING VERSION WITH RESERVOIR Fixing bracket Identifying tag ELECTRIC Minimum level Reservoir fill inlet G Lubricant outlet Rp Dual acting inlet outlet G Control cylinder Reservoir Level check d...

Page 4: ...al posture or possible impact Do not install the pump submerged in liquids and or in aggressive environments Do not install the pump in environments where there are explosive or flammable mixtures Ens...

Page 5: ...ype of lubricant Depending on these variables to achieve a proper supply to the delivery point it is always necessary to ensure that the pipeline pressure loss plus the pressure required at the lubric...

Page 6: ...tighten all the fittings ensuring that there are no leaks The piston of the pumping element is worn out Replace the piston The delivery valve is blocked Replace the valve The pump does not dispense lu...

Page 7: ...t disposal Upon demolition of the pump the identification label and any other document must be destroyed 11 ORDER INFORMATION Version WITH RESERVOIR for GREASE Part number Command Grease Characteristi...

Page 8: ...050 523 20 6 736 28 97 196 7 7 280 11 02 75 2 95 3414022 511 20 1 661 26 02 192 3 5 276 10 86 75 2 95 3414014 Dual acting 511 20 1 761 29 9 192 3 5 276 10 86 75 2 95 Version WITHOUT RESERVOIR for OIL...

Page 9: ...NBR gasket compatible lubricants Any residual lubricant inside that was used for assembly and testing is NLGI 0 grade 15 CONTRAINDICATIONS OF USE Compliance with the essential safety requirements and...