background image

C20008IE – Pneumatically driven pump  -  Rev. 0                February 99                 Page 9 of 9                  

CE Declaration Of Conformity 

 

 

Manufacturer : 

 

DROPSA SpA 

 

 

 

 

 

 

Company 

 

Via Croce, 1 - 20090 Vimodrone (MI), Italy 

 

 

Address 

 

02 - 250791 

 

 

 

 

 

 

 

 

Telephone 

 

It is certified that: 

           The machine: 

Pneumatically driven pump, type 3413…     and  31030.. 

 

∗ 

is manufactured in conformity with the DIRECTIVE OF THE COUNCIL OF THE EUROPEAN COMMUNITY concerning 
the harmonisation of member states legislation relative to machines (89/392/CEE + 91/368/CEE), EMC (89/336/CEE) and 
BT (73/23/CEE) and relative amendments.

 

∗ 

 is manufactured in accordance with the following standards and harmonised technical specifications:

 

 

EN 292/1, EN 292/2, EN 50081-2, EN 50082-2, CEI EN 60204-1, EN 1050. 

 

Technical manager 

 

 

Ing. Walter Divisi 

Product manager 

Name  

 

DROPSA SpA    -  Vimodrone (MI)  -  Italy

 

Company 

 
                                                                                            

   February 1999

 

Signature 

Date 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 DROPSA DISTRIBUTORS

 

Summary of Contents for 3103014

Page 1: ...WARNING 1 0 DESCRIPTION OF THE PUMP 2 0 TECHNICAL SPECIFICATIONS 3 0 CORRECT USE 4 0 INSTRUCTIONS FOR ORDERING AND DISTRIBUTORS DECLARATION OF CONFORMITY Catalogue P N C2008IE Wk 05 99 Registered nam...

Page 2: ...ubject the pump the tubing or other parts under pressure to violent impacts damaged tubing or connections are dangerous and should be replaced After prolonged periods of inactivity ensure the tightnes...

Page 3: ...ECIFICATIONS 2 1 Methods of commanding the pump Manual push button control 3 way solenoid valve control Mechanical roller or cam bar control Supply Supply Supply Discharge Discharge Discharge C20008IE...

Page 4: ...this purpose beforehand by the supplier For correct fixing verify the distance between centres shown in the diagram in Section 2 2 Use gloves and safety glasses as required in the lubrication oil safe...

Page 5: ...r at a minimum temperature of 5 C 3 4 Assembly Disassembly No pump assembly operations are envisaged For wall or floor mounting ensure adequate space is available as shown in the installation diagram...

Page 6: ...mbly The following should be checked periodically VERIFY WORK CYCLES The state of lubrication 100 The oil level 200 The cleanliness of the suction filter 400 The cleanliness of the loading return filt...

Page 7: ...Machine Directive is effected by means of the compilation of a check list which has been pre prepared and is contained in the technical file The lists which are utilised are of three types list of dan...

Page 8: ...NLGI1 30 1 5 0 5 2 YES 3413014 Pneum S A NLGI1 30 1 10 0 5 2 NO 3413016 Pneum S A NLGI1 30 1 5 0 5 2 YES with loading filter 3413018 Pneum S A NLGI1 30 1 3 0 5 2 YES 3413019 Pneum S A NLGI3 30 1 10 0...

Page 9: ...RECTIVE OF THE COUNCIL OF THE EUROPEAN COMMUNITY concerning the harmonisation of member states legislation relative to machines 89 392 CEE 91 368 CEE EMC 89 336 CEE and BT 73 23 CEE and relative amend...

Page 10: ......

Page 11: ......

Reviews: