background image

 

M

M

A

A

N

N

U

U

A

A

L

L

 

 

P

P

U

U

M

M

P

P

 

 

M

M

A

A

N

N

U

U

A

A

L

L

 

 

P

P

U

U

M

M

P

P

 

 

F

F

O

O

R

R

 

 

S

S

I

I

N

N

G

G

L

L

E

E

-

-

L

L

I

I

N

N

E

E

 

 

O

O

I

I

L

L

 

 

L

L

U

U

B

B

R

R

I

I

C

C

A

A

T

T

I

I

O

O

N

N

 

 

S

S

Y

Y

S

S

T

T

E

E

M

M

S

S

 

 

W

W

I

I

T

T

H

H

 

 

S

S

E

E

R

R

I

I

E

E

S

S

 

 

1

1

2

2

1

1

0

0

0

0

 

 

M

M

E

E

T

T

E

E

R

R

I

I

N

N

G

G

 

 

U

U

N

N

I

I

T

T

S

S

 

 

Piston pump for supplying lubrication systems using Single-Line (01) 

metering units. Centrally mounted with respect to the two lines 

enables the length of the system to be extended. It can be used with 

a single outlet by closing the other one using appropriate plug. 

By pulling up the control lever, the metering-unit cylinder is filled 

and a spring is loaded, which, upon release of the lever, acts on the 

piston, pressing fluid into the delivery pipeline. 

 

R

ELATIVE VALUE

 

The relative value determines the number of Single-Line 01 metering 

units that the pump can continuously supply for a minimum period 

of 5 minutes. In the case of systems with metering units having the 

same flow rate, the total number is obtained by dividing the relative 

number by the relative value of the metering unit. 
In the case of metering units with different flow rates, the relative 

values of each metering unit are added, thereby ensuring that the 

total does not exceed the relative value of the pump. 
The relative value of one metering unit corresponds to the number 

of drops distributed within a single minute (one drop = 33 mm

3

). 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NUMBER OF METERING UNITS SUPPLY BY THE PUMP WITH A RELATIVE VALUE OF 90 

Metering unit code 

Relative value 

Number of metering units 

00/aa 

0.75 

120 

0/a 

90 

1/b 

45 

2/c 

22 

3/d 

11 

4/e 

16 

5/f 

32 

 

 

 

 

C

C

H

H

A

A

R

R

A

A

C

C

T

T

E

E

R

R

I

I

S

S

T

T

I

I

C

C

S

S

 

 

A

A

P

P

P

P

L

L

I

I

C

C

A

A

T

T

I

I

O

O

N

N

S

S

 

 

I

I

N

N

S

S

T

T

A

A

L

L

L

L

A

A

T

T

I

I

O

O

N

N

 

 

Fill the reservoir with fluid to be pumped and repeatedly actuate the lever until fluid 

comes out. 

 

CAUTION:

 Upon installation, in order to enable pumping to be triggered, close the 

delivery holes during the fluid suction phase. 

 

 

M

M

A

A

I

I

N

N

T

T

E

E

N

N

A

A

N

N

C

C

E

E

 

 

Check the filter periodically in order to avoid clogging. The filter must be cleaned at least 

two times a year. If necessary, clean it using oil or petrol. 

To dismantle the filter, it is necessary to remove the reservoir by rotating it counter-

clockwise (the reservoir is attached to the pump’s body) removes the filter from its base. 

 

 

M

AX

.

 PRESSURE

:

 

3

 BAR

 

 

R

ESERVOIR CAPACITY

:

 

400

 CM

3

 TRANSPARENT

 

 

F

LOW RATE

:

 

15

 CC PER 

STROKE

 

 

C

OUPLINGS

:

 

R

1/8”

 

THREAD 

UNI

 

ISO

 

7/1 

 

S

UCTION FILTER

:

 

40

 

MICRONS

 

 

P

ERMITTED 

LUBRICANTS

:

 

O

IL WITH A 

VISCOSITY RANGING 
BETWEEN 

100

 AND 

250

 

C

S

T AT THE FLUID

OPERATING 
TEMPERATURE

 

R

ELATIVE VALUE

:

 

90 

 

 

L

UBRICATION 

SYSTEMS USING 

SINGLE

-

LINE 

METERING UNITS

 

 