5.1 Communication Failure Checklist
1. Stop Ignitions and Dropping:
SWITCHES OFF, SYSTEM STOPPED
2. Alert Operators and Bystanders:
ALERTED
3. Visually Verify Dropping Stopped:
DROPPING STOPPED
If dropping does not stop and the drone is under control, keep the drone over an area
where ignitions are safe before proceeding to the next step.
4. Return Drone to Landing Zone and Land:
LANDED
5. Perform Post Flight Inspection:
COMPLETE
5.2 In-Flight Fire Checklist
1. Check for In-Flight Fire:
FIRE SUSPECTED
2. Disarm Ignis:
DISARMED
3. Fly Over Safe Ignition Area:
OVER SAFE IGNITION AREA
4. Trigger Dropper Emergency Ejection:
TRIGGERED, EJECTED
5. Return Drone to Landing Zone and Land:
LANDED
6. Perform Post Flight Inspection:
COMPLETE
5.3
Stuck Ignition Sphere After Landing Checklist
1. Remove Needle Assemblies:
NEEDLES REMOVED
2. Trigger Dropper Emergency Ejection:
TRIGGERED, EJECTED
3. Battery Disconnect:
DISCONNECTED
4. Manually Remove Stuck Ignition Sphere:
REMOVED
6 Amplified Emergency Procedures
6.1 Communication Failure Checklist
If there is a communication failure between Ignis and the drone or between the ground
station and the Drone/Ignis, the system should automatically stop ignitions.
6.1.1 Stop Ignitions and Dropping
Stop Ignitions and Dropping:
SWITCHES OFF, SYSTEM STOPPED
Press the Stop button in the app to stop dropping. Disarm Ignis in order to prevent
accidentally starting again. On the M600 system move the Arm/Disarm switch (S3) on the
control bar into the disarm position (down and away from the user), as shown in
. For the Alta X and IF 1200 press button C as shown in
. This will safely
Last Updated
Page 48