background image

 ULTRA FLAME 

 

FIREPLACE GAS INSERT 

 
 
 
 

INSTALLATION AND OPERATING INSTRUCTIONS 

 
 

 

FOR YOUR SAFETY

 

 
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND 
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. 

 
 

FOR YOUR SAFETY 

 

 

 

 

IF YOU SMELL GAS : 

   1. 

OPEN 

WINDOWS 

 

 

 

2. TURN OFF MAIN GAS SUPPLY 

 

 

 

3. DON’T TOUCH ELECTRICAL SWITCHES 

 

 

 

4. EXTINGUISH ANY OPEN FLAME 

 

 

 

5. IMMEDIATELY CALL YOUR GAS SUPPLIER 

 
 
 

 

Tested by :

 

 

 

Manufactured by : 
 

 

 

 

 

 

DROLET STOVES & FIREPLACES INC. 

1700, Leon-Harmel 
Quebec, Qc (Canada) 

WARNOCK HERSEY 

G1N 

4R9 

   

 

 

 

 

 

         Rev. 

07/96 

45028A 

Summary of Contents for 36C03U TYPE 139

Page 1: ...DS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE FOR YOUR SAFETY IF YOU SMELL GAS 1 OPEN WINDOWS 2 TURN OFF MAIN GAS SUPPLY 3 DON T TOUCH ELECTRICAL SWITCHES 4 EXTINGUISH ANY OPEN FLAME 5 IMMEDIATELY...

Page 2: ...REMOVAL AND INSTALLATION 12 LOG INSTALLATION 13 FACE PLATE ASSEMBLY AND INSTALLATION 14 15 REFRACTORY PANELS INSTALLATION 16 EMBERS KIT INSTALLATION 16 OPERATING INSTRUCTIONS 17 LIGHTING INSTRUCTIONS...

Page 3: ...d thermo switch Your fan will therefore turn itself on or off automatically if you so desire The ULTRA FLAME should only installed in a existing masonry or prefab fireplaces The installation must be i...

Page 4: ...ILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON MORE FREQUENT CLEANING MAY...

Page 5: ...t pressure 7 14 in w c Vent size 4 Diam listed gas liner Valve Natural gas Propane White Rogers Robertshaw Model 36C03U TYPE 139 Model 7000 MVRLC Millivolt operated Millivolt operated SIT SIT Nova mod...

Page 6: ...TOP SIDE AND FRONT VIEWS 5...

Page 7: ...ance using the two bolts located in the back corners Mark the location for the gas inlet pipe We suggest using the hole in the back of the ULTRA FLAME for ease of connection 6 Remove the ULTRA FLAME g...

Page 8: ...ng the draft hood in place To do so fix two ropes to the draft hood sliders Make sure the draft hood front lip is squeezed under the steel angle to prevent any motion The probe tube must go through th...

Page 9: ...SE OPEN FLAME TO CHECK LEAKS 17 If you decided to make a direct connection to the fan step 8 remove the power cord and connect the 120 V line To do so unscrew the speed control unit and pull away from...

Page 10: ...the wires in serial with the face plate flame switch green wires NOTE DO NOT CONNECT THE WALL SWITCH WIRE OR THE VALVE TO 120 VOLTS POWER SUPPLY LINE THE VALVE IS OPERATED BY ITS OWN MILLIVOLT SYSTEM...

Page 11: ...on page 13 22 If so desired install the embers kits as shown on page 16 23 Install the glass front following page 11 instructions 24 Install the face plate according to page 14 instructions 25 Install...

Page 12: ...aps and water do not use abrasive cleaners which could remove the coating on the glass WARNING Do not clean when hot turn off the fireplace at least 30 minutes before removing the glass front The glas...

Page 13: ...back in the firebox and push to the right until it touches the firebox side Make sure the main orifice is inserted in the venturi tube by looking through the square hole as shown A silicone washer in...

Page 14: ...sure the log is pushed against the metal retainer on the burner face 4 Place the front of the log with a hole in the second notch from the left in the log holder at the front of the burner and positio...

Page 15: ...NING Do not invert the top and bottom louver assemblies this would damage them because top louvers can withstand to higher temperature They are marked with stickers at one end 3 Bolt the face plate le...

Page 16: ...e top louver and the bottom of the top piece Secure using four 10 x 1 2 metal screws D 3 Connect the slip on the terminals on the rocker switch making sure the wires are in pairs by color The green wi...

Page 17: ...to simulate ashes in the firebox another contains lava rocks to simulate coals and the other one contains fibreglass mat which when glowing red resembles hot embers 1 Place some vermiculite and lava...

Page 18: ...witch to the ON position If you don t have an additional wall switch the main burner will come on Otherwise turn the wall switch to ON if you want the main burner to come on 7 The other knob controls...

Page 19: ...necessary as described below or clean the pilot orifice if re adjustment is not possible Check the burner for flame lifting or for usual flame pattern If necessary clean the burner orifice Keep the ar...

Page 20: ...PLACEMENT PARTS ITEM DESCRIPTION Part No QTY Log kit 2232 1 Back log only 2232 BACK 1 Front log only 2232 FRONT 1 Top log small only 2232 SMALL 1 Top log holed only 2232 HOLED 1 Burner assembly 7950 1...

Page 21: ...to the fifth year of the limited warranty DROLET STOVES AND FIREPLACES INC will replace defective parts free of charge except the VALVE IGNITION CONTROL BURNER CONTROL DROLET STOVES AND FIREPLACES INC...

Reviews: