Safety Notice  ................................................................ 02
Unit Illustration ............................................................... 06
Important Testing Guidelines ........................................ 09
Quick Start ..................................................................... 10
Unit Operation  .............................................................. 12
  Battery Installation ..................................................... 12
  System Settings ........................................................ 13
  Applying The Wrist Monitor ....................................... 16
 Testing ....................................................................... 18
  Power Off .................................................................. 23
  Memory Check & Last 3 Tests Average .................... 25
  Memory Deletion ....................................................... 27
  Low Battery Indicator ................................................ 28
 Troubleshooting ........................................................ 29
Blood Pressure Information .......................................... 30
Blood Pressure Q&A ..................................................... 34
Maintenance  ................................................................. 36
Specifications ................................................................ 40
Warranty Specifications ................................................. 44

Thank you for purchasing the BP3200 Blood Pressure Monitor.

The unit has been constructed using reliable circuitry and durable 

materials. Used properly, this unit will provide years of satisfactory use.

The device is intended for used by individuals 12 years and older to 

measure the systolic and diastolic blood pressure and pulse rate. All 

values can be read out in one LCD DISPLAY. Measurement position is on 

adult upper arm only.

Blood pressure measurement determined with this device are equivalent 

to those obtained by a trained observer using the cuff/ stethoscope 

auscultation method, within the limits prescribed by the American National 

Standard (ANSI/AAMI Sp10) for electronic sphygmomanometers.

Precautions to Ensure Safe, Reliable Operation

1. Do not drop the unit. Protect it from sudden jars or shocks.

2. Do not insert foreign objects into any openings.

3. Do not attempt to disassemble the unit.

4. Do not crush the pressure cuff.

5. If the unit has been stored at temperatures below 0 oC, leave it in a warm 

place for about 15 minutes before using it. Otherwise, the cuff may not inflate 

properly.

6. Do not store the unit in direct sunlight, high humidity or dust.

7. To avoid any possibility of accidental strangulation, keep this unit away from 

children and do not drape tubing around your neck.

8. Ensure that children do not use the instrument unsupervised; some parts are 

small enough to be swallowed.

9. Some may get a skin irritation from the cuff taking frequent readings over the 

course of the day, but this irritation typically goes away on its own after

the monitor is removed.

7. People suffering from arrhythmias such as atrial or ventricular 

premature beats or atrial fibrillation only use this blood pressure 
monitor in consultation with your doctor. In certain cases oscillometric 
measurement method can produce incorrect readings.

8. Too frequent measurements can cause injury to the patient due to blood 

flow interference.

9. The cuff should not be applied over a wound as this can cause further 

injury.

10. Do not attach the cuff to a limb being used for IV infusions or any other 

intravascular access, therapy or an arterio-venous (A-V) shunt. The cuff 
inflation can temporarily block blood flow, potentially causing harm to the 
patient.

11. The cuff should not be placed on the arm on the side of a mastectomy. 

In the case of a double mastectomy use the side of the least dominant 
arm.

12. Pressurization of the cuff can temporarily cause loss of function of 

simultaneously used monitoring equipment on the same limb.

13. A compressed or kinked connection hose may cause continuous cuff 

pressure resulting in blood flow interference and potentially harmful injury 
to the patient.

14. Check that operation of the unit does not result in prolonged 

impairment of the circulation of the patient.

15. Product is designed for its intended use only. Do not misuse in any way.

Important Instructions Before Use
1.    Do not confuse self-monitoring with self-diagnosis. Blood pressure 

measurements should only be interpreted by a health professional who 
is familiar with your medical history.

2.     Contact your physician if test results regularly indicate abnormal 

readings. 

3.     If you are taking medication, consult with your physician to determine 

the most appropriate time to measure your blood pressure. NEVER 
change a prescribed medication without first consulting with your 
physician.

4.     Individuals with serious circulation problems may experience 

discomfort. Consult your physician prior to use.

5.     For persons with irregular or unstable circulation resulting from diabetes, 

liver disease, arteriosclerosis or other medical conditions, there may be 
variations in blood pressure values measured at the wrist versus at the 
upper arm. Monitoring the trends in your blood pressure taken at either 
the arm or the wrist is nevertheless useful and important.

6.     People suffering from vascular constriction, liver disorders or diabetes, 

people with cardiac pacemakers or a weak pulse, and women who are 
pregnant should consult their physician before measuring their blood 
pressure themselves. Different values may be obtained due to their 
condition.

Safety Notice

Safety Notice

Safety Notice

Wrist Type

Owner’s Manual

Deluxe Automatic Blood Pressure Monitor 

Wrist Model

MODEL BP3200

Summary of Contents for BP3200

Page 1: ...asurement method can produce incorrect readings 8 Too frequent measurements can cause injury to the patient due to blood flow interference 9 The cuff should not be applied over a wound as this can cau...

Page 2: ...lassification Indicator Monitor Unit Systolic Blood Pressure Diastolic Blood Pressure Pulse Rate M Button START STOP Button SET Button Wrist Cuff Contents Display 1 Monitor Unit 3 Plastic Storage Case...

Page 3: ...group 3 Time Format Setting Press SET button again to set the time format mode Set the time format by adjusting the M button EU means European Time US means U S Time 4 Save Settings While in any sett...

Page 4: ...y measurements for systolic and diastolic blood pressure An indicator representing the current measurement will appear next to the corresponding WHO Classification Note Refer to Page 31 32 for detail...

Page 5: ...too extreme while testing press the START STOP button to turn power off The cuff pressure will rapidly dissipate once the unit is off Press the M button again you may check past test results Upon acti...

Page 6: ...aken in a clinical or medical environment This is known as White Coat Hypertension and may be caused by feeling anxious or nervous Note Abnormal test results may be caused by 1 Improper cuff placement...

Page 7: ...y a small amount of rubbing alcohol to a soft cloth to clean cuff s surface Use a damp cloth water based to wipe clean Allow cuff to dry naturally at room temperature 7 Do not disassemble product 8 It...

Page 8: ...supplier and check the terms and conditions of the purchasing agreement This product should not be mixed with other commercial wastes for disposal This product is free of hazardous materials The Bloo...