ATEX Annex
5.1 ATEX zone classification
This Annex is an integral part of the sale of the SIT TRASCO
®
coupling according to the ATEX Directive 2014/34/EU, contains the
Declaration of Conformity, and, therefore, is delivered together with the coupling.
The User and Maintenance Manual, may be downloaded in electronic format on the website
The analysis of the coupling machining process was carried out by SIT S.p.A.
Below is the cross reference between hazardous zones, substances and categories according to the ATEX Directive 2014/34/EU.
CAUTION!
These instructions must be complied with in addition to the
warnings provided in the technical specifications.
SUBSTANCE
ZONE
ZONE DESCRIPTION
ATEX CATEGORY/MARKING
EPL
GASES, VAPOURS, MISTS
Zone 0
A place in which an explosive atmosphere,
consisting of a mixture with air of dangerous
substances in the form of a gas, vapour or
mist, is present continuously or for long
periods or frequently (>1000 hours/year).
1G
Ga
Zone 1
A place in which an explosive atmosphere,
consisting of a mixture of air of dangerous
substances in the form of a gas, vapour or
mist, is likely to occur in normal operation
occasionally (10 - 1000 hours/year).
2G or 1G
Gb or Ga
Zone2
A place in which an explosive atmosphere,
consisting of a mixture of air of dangerous
substances in the form of gas, vapour
or mist, is not likely to occur in normal
operation but, if it does occur, will persist
for a short period only (<10 hours/year).
3G, 2G or 1G
Gc, Gb or Ga
DUSTS
Zone 20
A place in which an explosive atmosphere, in
the form of a cloud of combustible dust in air
is present continuously or for long periods or
frequently (>1000 hours/year).
1D
Da
Zone 21
A place in which an explosive atmosphere,
in the form of a cloud of combustible dust
in air, is likely to occur in normal operation
occasionally (10 - 1000 hours/year).
2D or 1D
Db or Da
Zone 22
A place in which an explosive atmosphere, in
the form of a cloud of combustible dust in air,
is not likely to occur in normal operation but,
if it occurs, will persist for a short period only
(<10 hours/year).
3D, 2D or 1D
Dc, Db or Da
Table 5.1 - ATEX zone classification