background image

07-01802H F412-230V EU F412-110V UK 

Legend Brands Holdings, Inc. 

Owner’s Manual 

LGR 7000XLi Dehumidifier 

Original Instructions  

Models F412-230V EU & F412-110V UK

 

LEGEND BRANDS HOLDINGS LTD.

 

22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS 

Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 

www.legendbrandseurope.com

 

Dri-Eaz® dehumidifiers reduce humidity in enclosed environments by removing water vapor 
from the air. This unit is rugged, durable and highly portable, making it ideal for water damage 
restoration, structural drying, construction, and other applications requiring temporary, high-
performance dehumidification.  

Patents: 

http://www.LBpatents.com

 

R E A D   T H E S E   I N S T R U C T I O N S

 

SAFETY INSTRUCTIONS 

 

 

 

 

WARNING! Do not alter or modify your dehumidifier 
in any way. Use only replacement parts authorized 
by Dri-Eaz Products, Inc. Modifications or use of 
unapproved parts could create a hazard and will 
void your warranty. Contact your authorized 
distributor for assistance. 

WARNING! Electric shock hazard, rotating fan 
hazard and hot surface hazards.  

  Inspect the power cord before use. If cord is 

damaged, do not use. Always grasp the plug (not 
the cord) to unplug. 

  Must be earthed. Insert three-prong plug on power 

cord into a matching electrically earthed outlet. Do 
not use adapter. Never cut off third prong. Do not 
use an extension cord.  

  The unit must be operated on a 230V or 110V outlet 

(as appropriate) circuit protected by a Residual 
Current Device device.  

  Keep motor and wiring dry. 

  Always unplug unit before cleaning or servicing. 

  Do not attempt to repair the unit. For service, contact 

your local distributor. 

FIRE HAZARD 

  Keep away from open flames and heat sources. 

  Do  not  use  or  store  where  vapors  from  gasoline, 

solvents, thinners or other  flammable materials may 
be present. 

BEFORE YOU BEGIN 

Warranty registration 

Warranty registration procedures vary by 
country/market. Contact your local distributor for 
assistance. Registration allows us to better assist you 
with using, maintaining or servicing your equipment and 
to contact you in case we have important safety 
information concerning your Dri-Eaz product. If you 
determine service is required, have your equipment 
model, serial number and original proof of purchase 
available and ask for assistance with obtaining a return 
material authorization (RMA). 

 

GROUNDING INSTRUCTIONS 

This unit’s plug must be inserted into an appropriate 
outlet that is properly installed and grounded in 
accordance with all local codes and ordinances. 

WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric 
shock. Check with a qualified electrician or service 
person if you are in doubt as to whether the outlets 
are properly grounded. Do not modify the plugs 
provided with the appliance 

– if the plugs do not fit 

the outlets, have proper outlets installed by a 
qualified electrician.  

This equipment is for use on circuits with a nominal 
rating of no more than 230V or 110V (as appropriate).  

Handle the unit carefully 

Always operate the unit on a stable, level surface. Do 
not drop, throw, or place where it could fall. Rough 
treatment can damage the unit, and may create a 
hazardous condition or void the warranty. 

This unit intended for household and commercial use.  

WARNING

 

Summary of Contents for LGR 7000XLI

Page 1: ...ng or servicing Do not attempt to repair the unit For service contact your local distributor FIRE HAZARD Keep away from open flames and heat sources Do not use or store where vapors from gasoline solv...

Page 2: ...information about creating an optimum drying environment contact your local distributor Set up drain hose The condensate pump connects to a plastic drainage hose This hose is equipped with a quick co...

Page 3: ...user System information can also be displayed These items are accessed by pressing DISPLAY MENU Each press of the key will display the next parameter When you reach the parameter you wish to adjust pr...

Page 4: ...on can be accessed by pressing DISPLAY MENU Each press of the key will display the next parameter see list below When you reach the parameter you wish to adjust press MENU SELECTION to increase the va...

Page 5: ...to 0 2 INLET OUTLET 100 80 115 30 For information only 3 GRAIN DPR XX GPP XX X g kg for 230V models 4 FILTER CLEANED XXX HRS 5 FILTER CLEANED 0 HRS Press to clear filter hours 5 COIL CLEANED XXX HRS 5...

Page 6: ...lls into the sump area 3 Press the PURGE key When the purge cycle is complete turn the unit off 4 Remove the external drain hose drain it carefully coil it and secure it with one of the straps provide...

Page 7: ...a lasting protective shine use an automotive interior cleaner As Needed Clean pump check valve and basin If the unit displays the message ER9 PUMP BLOCKED PUMP HOSE the pump check valve and pump basin...

Page 8: ...n Allows system pressure to equalize None UNIT ON XXXX HRS INLET XXX F XX First line indicates total operating hours Second line Toggles between inlet temperature and inlet RH every 2 seconds None HUM...

Page 9: ...ror persists contact service ER7 INVALID MODEL SETTING Incorrect or unsupported DIP switch settings Contact Dri Eaz service department for correct DIP switch settings ER8 BUTTON STUCK ALL BUTTONS Key...

Page 10: ...exceed 71 dB Does not exceed 71 dB Air filter 3M HAF filter Part no F368 24 pack 3M HAF filter Part no F368 24 pack Drain hose 12 2 m 12 2 m Power cord 7 6 m 7 6 m Construction Rotomolded shell Rotom...

Page 11: ...07 01802H F412 230V EU F412 110V UK 11 Legend Brands Holdings Inc ELECTRICAL SCHEMATIC...

Reviews: