Dri-Eaz HydroSensor I Owner'S Manual Download Page 1

07-00315E F245, F251 

Dri-Eaz Products, Inc. 

 

Owner’s Manual 

HydroSensor I & II Moisture Probes 

Models F245, F251 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030

 

Fax: 360-757-7950

 

 

http://LegendBrandsRestoration.com

  

Conveniently detect moisture in carpets, pads, furniture, walls and other materials.  

Patents: http://www.LBpatents.com 

R E A D   A N D   S A V E   T H E S E   I N S T R U C T I O N S

 

 

NOTICE: The sensor points of the 

HydroSensor probe are extremely sharp. Take care 
when collapsing the telescoping tubes to avoid the 
points extending by accident. This could cause 
injury. Always retract the probe points into the shaft 
when not in use.

 

BEFORE YOU BEGIN 

Warranty registration 

Visit 

warranty.LegendBrandsRestoration.com

 to register your 

purchase. Registration allows us to better assist you with us-
ing, maintaining or servicing your equipment and to contact 
you in case we have important safety information concerning 
your Dri-Eaz product. If you determine service is required, 
have your equipment model, serial number and original proof 
of purchase available and call your distributor for assistance 
with obtaining a return material authorization (RMA).  

INTRODUCTION 

The HydroSensor Moisture Probes I & II are designed to detect 
moisture in carpets, cushion, floors, walls, furniture and other 
materials. When the probe tips are pushed into materials to 
penetrate the surface, an electric current is sent between the 
probes. The amount of moisture present in the material deter-
mines how easily the electrical current passes from one probe 
to the other. 

When moisture is present in a material, the light on the Hy-
droSensor will flash and the transducer will beep. The faster 
the rate of flashing and beeping, the higher the level of mois-
ture.  

The 7/8” probe tips are long enough to penetrate shag carpets, 
cushion, and flooring materials. With care, the HydroSensor 
can also be used to find moisture in furniture, walls, and ceiling 
materials.  

The HydroSensor will also detect the presence of urine resi-
dues. This is because urine salts attract and hold enough 
moisture to be detected. A black-light is recommended to con-
firm that urine is present. 

OPERATION 

1.  When  using  the  HydroSensor  II,  first  extend  the  shaft. 

Grasp  the  smaller-diameter  tube  and  slide  it  out  until  the 
spring button pops into place. 

2.  Extend the sensor points at the bottom of the probe. Loosen 

the  black  plastic  knob.  Push  it  down  and  around  the  S-
shaped slot, then tighten the knob to lock in position. 

3.  Test the unit by placing your fingers across the shaft of the 

points. The indicator lamp will light and the unit will beep.  

4.  Probe the suspected moisture area with the points. Flash-

ing and beeping indicates that carpet and/or pad are wet. A 
faster  rate  of  beeping/flashing  indicates  a  higher  level  of 
moisture. 

5.  Take care not to apply too much force on the probe. Excess 

force may damage the tips or telescoping tubes. 

6.  Always retract the sensor points when not in use. 

 

 