The Dragon X2 Mobile Furnace is an indirect fired furnace providing heated air for water damage restoration, 

structural drying, construction, event shelters and other temporary heating applications. 

 

R E A D   A N D   S A V E   T H E S E   I N S T R U C T I O N S

 

Safety Information 

Read this Owner's Manual carefully to learn how to 
properly operate and service your Dragon X2 Mobile 
Furnace. This manual should be kept permanently with 
the unit and remain with the Dragon if you sell it. 
 
 
 
 
 
 
 

 
 
 
 
 
 
WARNING! Failure to comply with the instructions 
and precautions provided in this Owner’s Manual 
can result in death, serious bodily injury, and/or 
property loss or damage from hazards of fire, 
explosion, burn, asphyxiation, carbon monoxide 
poisoning, and/or electrical shock. 

 

WARNING! Read this manual carefully before you 
use the heater.  

  Keep this document near the heater.  

  Follow the procedures as written.  

  Do not lean or sit on the heater.  

  Do not stand closer than 8 ft. (2 m) from the outlet of 

the heater.  

  Make sure there is sufficient air circulation around 

the unit for adequate combustion.  

  Keep all flammable material away from the heater.  

  Only do repair and maintenance after the heater has 

cooled sufficiently and the heater is disconnected 
from the electric power.  

 
WARNING! Check the Dragon X2 for proper air-to-
fuel ratio before each use. Failure to adjust for 
altitude changes could cause injury, permanent 

damage to the unit and secondary damage when 
ducting into a structure. It may also void the Dri-Eaz 
warranty. Refer to “Adjusting for Altitude,” p. 4, for 
instructions. If you have any questions, please call 
Dri-Eaz Service at 800-932-3030. 
 
WARNING! Breathing Hazard  

Fuel exhaust contains deadly carbon monoxide gas. 
Operate the Dragon only outdoors in open area. 
NEVER operate indoors or in enclosed spaces. 

WARNING! Fire and Explosion Hazard 

  Burner produces sparks and flame and unit 

becomes hot during use.  

  Keep away from flammable vapors, such as those 

from gasoline, paint thinner or solvents.  

  Keep away from combustible dusts, such as coal 

dust or sawdust.  

  Keep unit at least 8 ft. (2 m) away from any com-

bustible material.  

  Keep children and pets away. 

  Diesel fuel is flammable and can be explosive. 

  Do not smoke while operating, servicing, or refueling 

the Dragon. 

  Before refueling, turn unit off, allow to cool and then 

unplug.  

  Hot surfaces can ignite fuel vapors.  

WARNING! Electric Shock Hazard 

  Unit must be grounded. Use only with 3-hole 

grounded outlet.  

  Never modify plug or use an adaptor. If an extension 

cord is needed, it must have a three-prong 
grounding plug and be rated for outdoor use. 

  Never operate the Dragon in pooled or standing 

water. If electrical components become wet, allow to 
dry before using. 

Product identification 

An identification plate is attached to the side of the unit. 
The plate shows the year of production, serial number, 
electrical supply requirements, airflow, fuel capacity, and 
a production code.  

WARNING

 

Service Questions: Contact Dri-Eaz at (800) 932-3030
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com

Summary of Contents for Dragon X2

Page 1: ...o before each use Failure to adjust for altitude changes could cause injury permanent damage to the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer...

Page 2: ...on Fuel type The Dragon X2 Mobile Furnace can operate for approxi mately 72 hours on a single tank depending on conditions The Dragon is designed to operate on no 1 or no 2 diesel or fuel oil In cold...

Page 3: ...tack to the flue opening by slipping the stack over the flue ring Figure 1 B If the stack does not fit snugly drive small sheet metal screws into the three pre drilled holes in the base of the stack t...

Page 4: ...e could damage the heat exchanger and will not be covered under warranty Special Instructions Bleeding the fuel line In certain circumstances air may accumulate in the fuel line and prevent proper ope...

Page 5: ...eset To manually reset the Dragon after a thermal overload shutoff 1 Open the hood by removing sheet metal screws and lifting The hood is hinged on one side 2 Turn the CONTROL KNOB to Thermostat 4 Pre...

Page 6: ...Replace the fuel filter once a year The filter is a spin on type and is located inside the right side cabinet behind the control panel Replacement fuel filters may be purchased from Johnston Supply p...

Page 7: ...hut off monitored by thermostat 102 F 38 8 C Automatic reset cut off No user intervention required 175 F 79 4 C High temperature cut off Manual reset required 205 F 96 1 C Fuel tank capacity 55 gal 20...

Page 8: ...e pare a menos de 8 pies 2 m de la salida del calentador Aseg rese de que haya suficiente circulaci n de aire alrededor de la unidad para que la combusti n sea adecuada Mantenga todos los elementos in...

Page 9: ...e temporalmente calor puro y seco Cuando se utiliza para reparar da os causados por el agua y secar construcciones nuevas el Dragon puede aumentar la eficacia de secado El calor que aporta el Dragon a...

Page 10: ...s ruedas cuando estacione el remolque Antes de cada viaje realice un control de seguridad del remolque Aseg rese de que La bola de remolque est bien colocada en el recibidor y el pasador de seguridad...

Page 11: ...te el tubo al transportar el Dragon ADVERTENCIA No utilice el Dragon si el tubo de escape no est colocado Coloque los conductos en el Dragon El Dragon incluye tres conductos de 25 pies de largo por 8...

Page 12: ...0 5 cm x 2 m recipiente para combustible trapos o pa os para limpiar cualquier derrame llaves de tuercas y destornillador 1 Gire la PERILLA DE CONTROL hasta la posici n Off 2 Abra la tapa Aseg rese d...

Page 13: ...ragon volver a funcionar con normalidad Para mayor seguridad el Dragon tambi n incluye un limitador de alta temperatura Si el intercambiador t rmico alcanza los 205 F 96 1 C el limitador apagar el Dra...

Page 14: ...drenaje para que caiga all el combustible b Quite el tap n de drenaje con una llave de tuerca c Deje que el tanque se vac e por completo d Vuelva a colocar el tap n de drenaje e Deseche el combustible...

Page 15: ...delo Calentador Port til Dragon X2 Portable Heater F429 Dimensiones con el remolque incluido ancho x altura x profundidad 74 54 116 in 1 9 1 4 3 m Peso 1500 lb 680 kg Peso total del veh culo 2000 lb 9...

Page 16: ...as se pencher ni s asseoir sur le g n rateur Ne pas s approcher moins de 8 pi 2 m de la sortie d air du g n rateur La circulation d air autour de l appareil doit favoriser une bonne combustion Garder...

Page 17: ...ocaux de stockage et les entrep ts les serres et les tunnels en polyur thanne pour l agriculture toute situation exigeant un chauffage temporaire sec et propre Le Dragon favorise un s chage plus effic...

Page 18: ...r un endroit non fr quent par les enfants ou les animaux V rifier que l entr e d air est bien d gag e MISE EN GARDE Les prises d air doivent tre propres sans engorgement viter de placer l appareil l o...

Page 19: ...es r glages du Dragon et les conditions dans la structure au moins une fois par jour de fonctionnement R gulation de la temp rature Le Dragon est muni d un thermostat distant permettant de r guler la...

Page 20: ...arburant L chappement du Dragon doit toujours tre transparent Une fum e noire ou blanche indique un mauvais m lange air carburant a Lorsque l chappement est transparent aucun r glage n est n cessaire...

Page 21: ...u refroidissement complet du g n rateur Suivre les instructions ci apr s de red marrage Conseil Les tapes suivantes doivent parfois tre r p t es trois quatre fois afin de permettre la pompe de carbura...

Page 22: ...service technique de Dri Eaz au 800 932 3030 l adresse du service apr s vente le plus proche 5 Nettoyage du bo tier Nettoyer le bo tier du Dragon avec un d graissant de type Unsmoke Degrease All Acces...

Page 23: ...1 06 Warranty 07 00424 23 Dri Eaz Products Inc Dragon X2 Schematic Esquema Schematic See Schematic Key p 24 Vea en la p gina 24 la explicaci n de los s mbolos utilizados en el esquema Voir l gende du...

Page 24: ...3 SJT CONJUNTO DE CABLES DEL TERMOSTATO 14 3 SJT FAISCEAU DE C BLES 24VAC 24VAC 24 V c a BLOWER VENTILADOR SOUFFLANTE BULB BOMBILLA AMPOULE BURNER QUEMADOR BR LEUR BURNER CONTROL SWITCH ADJUST TO 175...

Reviews: