SECTION 5
MAINTENANCE
Page 34
OM515C520C99/1E
DRESSTA
ENGINE
IMPORTANT:
Use ST-1293 belt tension gauge to check belt tension.
Fig. 5.21. Checking Belt Tension
5.11.4. CHECKING THE CONDITION OF FAN AND HUB
WARNING! Damaged fan blades may cause serious injury. Never pull the fan
blades nor lift them. This may damage the fan and cause injury.
Radiator fan must be checked every day (Fig. 5.22). Check for cracks, loose rivets and bent or
loose blades. Check the fan to make sure it is securely mounted. Replace any fan that is damaged.
Check the fan hub every 1000 hours of operation. It should rotate freely although without excessive
loose.
Fig. 5.22. Checking for Fan Defects