b. Is the plasma stable (that is, is the plasma producing a constant glow)?
If not, see
“Troubleshooting Guide” on page 6-2
.
9. If you have a matching network connected, did the capacitors begin to
move? If not, see
“Matching Network Troubleshooting” on page 6-2
.
10. Vary the chamber conditions according to your process requirements, and
verify that the CESAR generator can cover the required load impedance
range.
Congratulations, you have successfully installed and operated the CESAR
generator.
To Operate the CESAR Generator for the First Time Using the 15-pin User Port:
1. If the generator is not connected to a system interlock loop, verify that
there is external contact closure between
Interlock
pins 1 and 2 (see
).
2. Power on the system by turning the front panel
ON/OFF
switch clockwise
to a vertical position.
The initial front panel screen will display the CESAR generator model
name, the operating frequency, the maximum RF power, and the
software version. After five seconds, the display will change to a standard
operation screen.
3. Listen to ensure the fans are rotating.
4. On the front panel, set the
Control by
setting to
User Port
(see
the Device Configuration Settings” on page 5-40
5. Verify that you have selected the desired power regulation mode:
4
See
User Port
pins 1 and 2 in
and
.
6. Apply the appropriate voltage to
User Port
pin 12 (
RF POWER SET
POINT
). See
for more information.
7. Apply the appropriate voltage to
User Port
pin 10 (
RF PWR ON
). See
for more information.
8. Check the load. If your load is a plasma:
a. Is the plasma lit? If not, you may have a faulty connector or too little
“Troubleshooting Guide” on page 6-2
b. Is the plasma stable (that is, is the plasma producing a constant glow)?
If not, see
“Troubleshooting Guide” on page 6-2
.
9. If you have a matching network connected, did the capacitors begin to
move? If not, see
“Matching Network Troubleshooting” on page 6-2
.
10. Vary the chamber conditions according to your process requirements, and
verify that the CESAR generator can cover the required load impedance
range.
Summary of Contents for CESAR 1312
Page 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Page 2: ......
Page 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Page 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Page 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Page 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Page 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Page 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Page 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...