![Dressler CESAR 1312 User Manual Download Page 120](http://html1.mh-extra.com/html/dressler/cesar-1312/cesar-1312_user-manual_2530911120.webp)
4-86
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
212
report serial
port 0
address
and baud
rate
This
command
is for AE
Bus only. It
can not be
used with
PROFIBUS
and
Ethernet
interfaces.
Returns the serial port address and baud
rate.
The controller returns three data bytes:
• Byte 1 is always address 1
• Bytes 2 and 3 = baud rate
4
9600
4
19200
4
38400
4
57600
4
115200
Note:
For 115200, the return value is 0
Set with command
69
.
0
3
223
report error
code
register
Retrieves the error code. See also
“Checking for and Resolving Errors and
Warnings” on page 6-7
0
1
230
report
sensor data
Returns sensor data:
• Bytes 0 and 1 = Reserved
• Bytes 2 and 3 = Condensation
0
4
231
report unit
serial
number
The controller returns four data bytes
representing the serial number (LSB first)
0
4
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for CESAR 1312
Page 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Page 2: ......
Page 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Page 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Page 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Page 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Page 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Page 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Page 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...