HPG 13150 400 V (A)
Communication Interfaces
4-55
HPG™ 13150 400 V RF Power Generator
Prerelease version
130
report
software
version
Reports the version of the software. The
returning packet contains 5 ASCII
characters.
This command is used in conjunction
with command
198
to obtain the version/
revision number of the software (for
example, C3STD).
0
5 data
bytes
5 ASCII
characters
131
report
motor
movement
Reports the match network motor
movement when the generator is
connected to a Variomatch unit through
the matching interface. (For more
information on this interface, see
“Matching Interface” on page 4-2
.) This
command will not work with other
matching networks unless they are
electrically compatible and are connected
through the
Matching Interface
connector.
Returns one data byte:
• 0 = Match network’s motors stopped
• 1 = Match network’s motors running
0
1
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes