4-44
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
12
Profibus
version
set target
life
(see
previous
row for AE
Bus/
Ethernet
version of
command)
Sets the target life, in kilowatt hours, of
the specified target (see command
11
).
• Byte 1 selects the target number (1
to 4).
• Bytes 2 and 3 specify the target life in
hundredths of kilowatt-hours (for
example, 100 = 1 kWh).
For more information, see
.
Read back with command
157
.
3
1
(CSR only)
13
tuner
control
Sets the tuner control if the HPG
generator is connected to a Dressler
Variomatch unit through the matching
interface. (For more information on this
interface, see
.) This command will not work
with other matching networks unless they
are electrically compatible and are
connected through the
Matching
Interface
connector.
Send one data byte:
• 0 = Manual
• 1 = Automatic
Note:
A Variomatch unit must be
connected to the generator.
1
1
(CSR only)
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...