Setting and Using Preset Generator Settings for Different
Applications
You can set the various front panel functions to meet your specific process
needs, and you can store up to five presets (1 through 5) for five different
applications. The presets store all settings in the program menu except pulse
input configuration and device configuration. Preset 0 is reserved for factory
settings and can be accessed read-only.
To Store a Preset Using the HPG Generator Front Panel:
1. Set all of the desired parameters using the front panel program menu (see
“Using the Front Panel Program Menu” on page 5-18
2. After you have made the appropriate program menu selections, you will
have the option to
Execute
,
Store Preset
, or
Quit
.
3. Press
Store Preset
. The settings for this particular preset will flash on the
front panel.
To Erase a Preset Using the HPG Generator Front Panel:
1. Go to the preset number you wish to erase. (When you select a number,
the settings for each particular preset will flash on the front panel).
2. Press
Quit
.
To Use a Preset:
1. Go the preset you wish to select. (When you select a number, the settings
for each particular preset will flash on the front panel)
2. Press
Execute
.
Controlling a Variomatch Unit Attached to the Generator
When a Dressler Variomatch is connected to the matching interface of the
HPG generator and set to manual tune, you can adjust the tune and load
positions using the following Matching controls on the front panel. (For
information on the matching interface, see
“Matching Interface” on page 4-2
Note:
These keys only control a Variomatch that is connected to the matching
interface of the generator. These keys can not be used to control any
other matching networks unless they are electrically compatible and are
connected through the
Matching Interface
connector.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...