HPG 13150 400 V (A)
Installation, Setup, and Operation
5-33
HPG™ 13150 400 V RF Power Generator
Prerelease version
This setting switches between internal pulsing and continuous
power with the pulse input at a high state.
4
Hi=Pulse
Low=CW
This setting switches between internal pulsing and continuous
power with the pulse input at a low state.
4
Off
This setting disables the pulse input. Normal internal pulsing is
used.
5. Press the
Exit
soft key.
6. Press the
Execute
soft key.
CHANGING THE DEVICE CONFIGURATION SETTINGS
The
Device Configuration
feature allows you to change the factory default
settings and customize the HPG generator to meet your specific needs. You
can change the following parameters:
•
Display contrast
Display contrast allows you to adjust the contrast (brightness) of the LCD
graphic display.
•
Analog I/O range
The analog interface level is factory set to the most common level range
of 0 V to 10 V. However, you may reprogram this value by changing the
maximum voltage of possible analog interface levels from 2 V to 10 V.
These levels apply to all analog inputs and outputs on the user port.
•
DC Bias Scaling
You may set the maximum DC bias in volts from 0 V to 4000 V (in
increments of 1, 10, 100, 10000, and Auto). 4000 V is the default value.
•
Control by
This feature lets you choose between
Front Panel
control and
User Port
control in which the generator will try to detect the
User Port
.
•
RS232 baud rate
If your HPG generator has an RS-232 port, this function allows you to
select the desired baud rate: 9600, 19200, 38400, 56000, or 115200.
Note:
To determine if you have an RS-232 port, see
Model 13150 400 V Options” on page 1-2
•
RS232 protocol
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...