HPG 13150 400 V (A)
Installation, Setup, and Operation
5-13
HPG™ 13150 400 V RF Power Generator
Prerelease version
SETTING FORWARD POWER REGULATION MODE
(P
FORWARD
)
In forward power regulation mode, the HPG Generator regulates RF power
with constant forward power. This section explains how to select forward
power regulation using the
User Port
, the
Host
port, or the front panel.
To Select P
forward
Regulation Through the User Port:
See pin 8 on the 25-pin
User port
“RF forward/load power regulation” on
.
To Select Forward Power Regulation Through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
HPG generator:
1. Select forward power regulation mode:
Send one data byte for command
3
(see
).
4
6 = Forward power regulation
2. Specify the output set point level for the regulation mode:
Send two data bytes, least significant byte first, for command
8
representing the set point level in watts (see
To Select Forward Power Regulation Using the HPG Generator Front Panel:
Complete the following steps to select P
forward
regulation using the front panel:
1. Press the
Program
soft key.
Control Settings
appears on the display.
2. Press
Change
.
3. Press
Control P
forward
.
4. Select the desired power set point between 0 W and 15 kW into a 50
Ω
nonreactive load using the
RF
POWER
dial knob. Press the
Increm Auto
soft key to toggle between dynamic increments (Auto) and several fixed
increments.
5. Press
Ok
to confirm.
6. Press
Exit
.
7. Press
Execute
.
The operating screen will then display the forward power in watts, the reflected
power in watts, and the
Program
and
Display
soft keys.
SETTING LOAD POWER REGULATION MODE (P
REAL
)
In load power regulation mode, the HPG Generator regulates RF power with
constant load (real) power. This section explains how to select load power
regulation using the
User Port
, the
Host
port, or the front panel.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...