5-10
Installation, Setup, and Operation
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
5. Set the Host control mode by sending
active control mode
command
14
4
2 =
Host
(serial) control
6. Select the desired regulation mode by sending
regulation mode
command
3
(for a description of regulation mode settings, see
4
6 = Forward power (P
forward
) regulation
4
7 = Load power (P
real
) regulation
4
8 = External power (DC Bias) regulation
Note:
You cannot change power regulation mode while RF power is on.
7. Send
set point
command
8
to set the set point.
8. Send
RF on
command
2
to turn on RF power.
9. Check the load. If your load is a plasma:
a. Is the plasma lit? If not, you may have a faulty connector or too little
“Troubleshooting Guide” on page 6-2
b. Is the plasma stable (that is, is the plasma producing a constant glow)?
If not, see
“Troubleshooting Guide” on page 6-2
.
10. If you have a matching network connected, did the capacitors begin to
move? If not, see .
11. Vary the chamber conditions according to your process requirements, and
verify that the HPG generator can cover the required load impedance
range.
Congratulations, you have successfully installed and operated the HPG
generator.
Operating the HPG Generator for the First Time Using the
Front Panel
You can operate the HPG generator using full front panel control or remote
control with partial front panel control. This section describes full front panel
control operation. For partial control (Remote Control Override), see
Remote Control Override” on page 5-29
.
To Operate the HPG Generator for the First Time Using the Front Panel:
1. Ensure that the
User Port
interlock signal is satisfied. Verify that there is
external contact closure between pins 10 and 23 (
INTERLOCK LOOP
).
See
for more information.
2. Apply water and ensure the water is flowing at or above the specified
).
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...