dreambaby Chelsea F170 B/W Instructions Manual Download Page 6

6

7. 

To open the gate:

 Slide the Gate Release Switch (7A). Lift the Gate Panel upward (7B). Gate swings open 

in both directions (7C).

OPERATION

8. 

To close the gate:

 Release the Gate and it will swing closed automatically. 

 

Try this action several times and make sure:

•  The Upper Lock Rod and the latch of the Switch are completely latched within the Lock Holder at 
  Right Upper Corner (8A).
•  The Lower Lock Rod of the Gate Panel fits securely into the Lock Holder of Gate Frame (8B).
•  The Warning Line has disappeared (8C & 8D).

Gate

Panel

Lock 

Holder

Gate Frame

Lower 

Lock 

Rod

8B

Warning line

8C

8D

The warning line will disappear when the gate is locked properly.

The warning line will appear RED color if the gate is opened or not locked properly.

RED

Right Upper 

Corner

Upper 

Lock Rod

Lock Holder

8A

7C

7B

7A

Gate Release

Switch

Slide

Lift Gate Panel 

up to open

Gate opens in 

both directions

Summary of Contents for Chelsea F170 B/W

Page 1: ...at the top of the stairs it should not be positioned below top level If the safety barrier is used at the bottom of the stairs it should be positioned at the front of the lowest tread possible This ga...

Page 2: ...A 1 Measure the width of the opening of where you intend to install the gate Ensure the surface that you are mounting the gate is structurally sound such as solid timber brick or masonry For plaster g...

Page 3: ...ert LONG END of EXTENSION PIN into Gate Frame Gate Frame 159 192 9cm 3 5in 171 193 18cm 7in 172 194 27cm 10 5in 831 841 36cm 14in 832 842 45cm 17 5in 833 843 54cm 21in 834 844 63cm 24 5in n i 9 3 m c...

Page 4: ...op are directly above the ones at the bottom WARNING 3A 3C 3D 3E 3E 3B Never use without Mounting Cups Top view of gate Side view of gate If the gate is used at the bottom of the stairs to prevent the...

Page 5: ...the top at the same time by turning them clockwise 5C 6 Tighten the Tension Knobs until the two Indicator Lines located on the Upper Locking Set and on the Right Upper Corner align horizontally 6A 5A...

Page 6: ...e Lock Holder at Right Upper Corner 8A The Lower Lock Rod of the Gate Panel fits securely into the Lock Holder of Gate Frame 8B The Warning Line has disappeared 8C 8D Gate Panel Lock Holder Gate Frame...

Page 7: ...ng gate in chosen direction to its maximum opening 9A Gate will stay open Close as required Caution When using the Stay Open System the automatic closing feature is not in operation Keep gate closed w...

Page 8: ...securely in place Do not use the safety gate if any components are damaged or missing To clean wipe surface with a damp cloth or sponge using mild detergent and warm water Never clean with abrasive am...

Reviews: