12.3 lut_mode <mode>
Selects the LUT operational mode.
Value
Reset
Minimal
Maximal
Mode
0
0
2
There are three operational modes available:
Mode
Description
0
Table based using interpolation. The user has to specify a table with a maximum
of 24 values.
Intended for offline calibration.
1
Fast gamma mode where the user only specifies the desired gamma value.
Can be used for gamma changes during runtime.
2
Fixed gamma mode where the user selects one of three fixed gamma tables.
12.4 lut_preset <index>
Selects the preset storage for the current LUT interpolator.
Value
Reset
Minimal
Maximal