E

N

 

Connection of the heater to electric network shall be executed following the plumbing fixture. In order to 
enhance the protection of coupling in bathrooms and shower corners pursuant to ČSN 332000-7-701, the 
appliance  is  provided  with  a  grounding  terminal  for connecting  with  a  yellow-green  protective  conductor 
on minimum section 4 mm2. Access to the electric part of the heater is enabled only upon disconnecting 
the heater from power supply and unscrewing the guard of the heater. 
 
The degree of protection of electric parts of the heater is IP 24. 
 
Respect the rules of protection against electricity injuries in accordance with ČSN 33 2000–4-41. 
 
 
 

9. HEATER COMMISSIONING 

  
Once connected to the water supply, the heater can be put in service. 
Procedure: 
a) 

check the power and water main installation 

b) 

open the hot water valve on the combination faucet 

c) 

open the cold water inlet valve to the heater. 

d) 

as soon as the water starts running through the hot water valve, the heater is filled and the valve 

closes. 
e) 

using the front-end main switch open electricity and thus the heater activates. 

 

 

Before first use, or after longer periods, it is necessary to ensure flushing, irrigation and 
ventilation heater before starting the heating. The first heating tank must be monitored. 

 

 

10. IMPORTANT NOTICE 

 

 

 

 

Without a confirmation issued by an authorised company about performed 
electrical and plumbing fixture the warranty certificate shall be void. 

 

The hot water outlet must be equipped with a combination faucet. 

 

It is not allowed to handle the thermostat in any manner whatsoever, aside 

from temperature resetting with a control button. 

 

 All electric installation handling, adjustment and replacement of the regulation 

elements shall only be performed by an authorised service company. 

 

The thermal fuse must not be turned off. The non-reversible thermal fuse 

discontinues electric power input to the heating element should the thermostat 
fail, if the water temperature in the heater exceeds 99°C.

 

 
Disposal of packaging material and functionless product 
 

A service fee for providing return and recovery  of packaging material has been 
paid for the packaging in which the water heater was delivered. 
Was paid pursuant to Act No. 477/2001 Coll., as amended, at EKO-KOM a.s. The 
client  number  of  the  company  is  F06020274.  Take  the  product  packages  to  a 
waste disposal place designated to that purpose by the municipality. When the 
operation  terminates,  disassemble  and  transport  the  discarded  and 
unserviceable heater to a waste recycling centre (collecting yard), or contact the 
manufacturer. 

 

Summary of Contents for TO 10 IN/UP

Page 1: ...10 IN UP TO 15 IN UP PREVADZKOVO MONTA NE PREDPISY OPERATING and INSTALLATION MANUAL BEDIENUNGS UND INSTALLATIONSANWEISUNG Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizero...

Page 2: ...10 D le it upozorn n 9 10 1 Likvidace obalov ho materi lu a nefunk n ho v robku 9 11 Funk n poruchy 10 12 Po rn p edpisy pro instalaci a u v n oh va e 10 13 Pou v n oh va e a dr ba 11 14 Instala n p...

Page 3: ...st v robku POZOR D le it upozorn n kter mus b t dodr eno P ED INSTALAC OH VA E SI POZORN P E T TE TENTO N VOD V en z kazn ku Dru stevn z vody Dra ice stroj rna s r o V m d kuj za rozhodnut pou vat v r...

Page 4: ...evu u itkov vody na doporu enou teplotu 60 C je cca 9 18 a 27 minut podle objemu V robek doporu ujeme pou vat ve vnit n m prost ed s teplotou vzduchu 2 C a 45 C a relativn vlhkost max 80 3 TECHNICK P...

Page 5: ...u it oh t ho objemu je pot eba nastavit termostat do polohy 9 C na knofl ku termostatu nastavit na zna ku sn hov vlo ka proti zamrznut 6 MONT NA ST NU P ed mont je t eba zkontrolovat nosnost st ny p p...

Page 6: ...kap n vody ale m ete jen po kodit sm ovac baterii P i uzav en m tlakov m syst mu p ipojen mus te na odb rov ch m stech pou t tlakov sm ovac baterie Na napou t c trubku mus te p ipojit pojistn ventil k...

Page 7: ...istn ho ventilu do provozu je nutn vykonat jeho kontrolu Kontrola se prov d ru n m odd len m membr ny od sedla pozdvihnut m t hla pojistn ho ventilu spr vn funkce odtrhovac ho za zen se projev odte en...

Page 8: ...anu proti razu elektrick m proudem podle SN 33 2000 4 41 Stupe kryt elektrick ch st oh va e je IP 24 9 UVEDEN OH VA E DO PROVOZU Po p ipojen oh va e na vodovodn d se m e uv st oh va do provozu Postup...

Page 9: ...oh va e vody do uzav en ch prostor mezistrop vestaveb a v klenk mus b t zaji t n dostate n p stup k obslu n m armatur m elektrick m svorkovnic m anod m a istic m otvor m Minim ln odstup od istic ho ot...

Page 10: ...ergie mimo oh va 4 Teplota vody v z sobn ku neodpov d nastaven hodnot Kontrolka sv t porucha termostatu Nepokou ejte se z vadu sami odstranit Obra te se bu na odbornou nebo servisn slu bu Odborn kovi...

Page 11: ...aterie Siln m uta en m rukojeti na sm ovac baterii kap n vody nezamez te m ete v ak baterii zni it Pokud oh va nebudete st le pou vat mus te vodu v oh va i chr nit p ed mrazem tak e elektrick proud zc...

Page 12: ...instalace budov SN 33 2000 7 701 Elektrick instalace n zk ho nap t Za zen jedno elov a ve zvl tn ch objektech Prostory s vanou nebo sprchou P edpisy a sm rnice kter je nutn dodr et p i p ipojen oh va...

Page 13: ...265 TO 15 UP 500 398 350 310 TO 15 IN 500 122 350 310 15 OBR ZKY 15 1 ROZM RY OH VA Proveden nad odb rn m sto Proveden pod odb rn m sto 15 2 SCH MA ELEKTRICK HO ZAPOJEN Legenda 1 Termostat 2 Tepeln p...

Page 14: ...os v robku preveril Stroj rensk zku ebn stav v Brne V robca si vyhradzuje pr vo na technick zmenu v robku V robok je ur en na trval styk s pitnou vodou Pre spr vnu funkciu mus by ohrieva vody pripojen...

Page 15: ...ohrevu itkovej vody na odporu en teplotu 60 C je cca 9 18 alebo 27 min t pod a objemu 3 TECHNICK POPIS N doba ohrieva a je oce ov smaltovan pre tlakov zapojenie elektrick vykurovacie teleso je meden S...

Page 16: ...prev dzke bez vyu itia ohriateho objemu je potrebn nastavi termostat do polohy 9 C proti zamrznutiu na gomb ku termostatu nastavi na zna ku snehov vlo ka 6 MONT NA STENU Pred mont ou je potrebn skontr...

Page 17: ...sa pri ohrievan objem vody zv uje a to sp sobuje kvapkanie vody z r rky mie acej bat rie Siln m u ahovan m ventilu mie acej bat rie sa nezamedz kvapkaniu vody m e sa v ak zmie avacia bat ria po kodi P...

Page 18: ...vodu v robcu poistn ho zariadenia Pred ka d m uveden m poistn ho ventilu do prev dzky je nutn vykona jeho kontrolu Kontrola sa vykon va ru n m oddialen m membr ny od sedla pooto en m gomb ka odtrhovac...

Page 19: ...ohrieva a Dodr iavajte ochranu pred razom elektrick m pr dom pod a SN 33 2000 4 41 Stupe krytia elektrick ch ast ohrieva a je IP 24 9 UVEDENIE OHRIEVA A DO PREV DZKY Po pripojen ohrieva a na vodovodn...

Page 20: ...i mont i ohrieva a vody do uzavret ch priestorov medzistropov vstavieb a v klenkov mus by zabezpe en dostato n pr stup k obslu n m armat ram elektrick m svorkovniciam anod m a istiacim otvorom Minim l...

Page 21: ...energie mimo ohrieva 4 Teplota vody v z sobn ku nezodpoved nastavenej hodnote Kontrolka svieti porucha termostatu Nepok ajte sa z vadu sami odstr ni Obr te sa na odborn alebo servisn slu bu Odborn ko...

Page 22: ...novan ho vypnutia V d sledku ohrievania sa objem vody zv o sp sob kvapkanie vody z r rok mie acej bat rie Siln m utiahnut m rukov te na mie acej bat rii kvapkaniu vody nezamedz te m ete v ak bat riu z...

Page 23: ...tal cia budov SN 33 2000 7 701 Elektrick in tal cie n zkeho nap tia Zariadenia jedno elov a v zvl tnych objektoch Priestory s va ou alebo sprchou P edpisy a smernice ktor je treba dodr a pri mont i o...

Page 24: ...P 500 398 350 310 TO 15 IN 500 122 350 310 15 Obr zky Obr 1 Rozmery ohrieva ov Prevedenie nad odbern miesto Prevedenie pod odbern miesto Obr 2 Sch ma elektrick ho zapojenia Legenda 1 Termostat 2 Tepel...

Page 25: ...ation for heater users Recommendations of manufacturer observance of which will ensure trouble free operation and long service life of the product CAUTION Important notice to be observed READ CAREFULL...

Page 26: ...about 9 and 18 minutes depending on the volume 3 TECHNICAL DESCRIPTION The heater tank is steel enamelled for pressure connection the electric heating element is copper The heater tank consists of ma...

Page 27: ...e light goes out In case of longer operation without using the heated volume the thermostat has to be set to position 9 C set the snowflake symbol on the thermostat button to avoid its freezing 6 WALL...

Page 28: ...losed pressure connection system you need to use pressurised combination faucets at the withdrawal points You have to attach a safety valve to the filling pipe to avoid increase of pressure in the tan...

Page 29: ...er may be dripping off the drain pipe of the safety valve the pipe must be open into the air pointed down environment temperatures must not drop below zero When draining the heater use a recommended d...

Page 30: ...and ventilation heater before starting the heating The first heating tank must be monitored 10 IMPORTANT NOTICE Without a confirmation issued by an authorised company about performed electrical and pl...

Page 31: ...ng a repair appointment report the type and serial number you find on the performance plate of your water heater 12 FIRE FIGHTING REGULATIONS FOR INSTALLATION AND USE OF HEATER We would like to emphas...

Page 32: ...the heater is maintained at the approximate temperature of 9 C If you take the heater off the power supply you have to drain the water from it if there is a risk that the water inside freezes Clean t...

Page 33: ...Regulations and instructions that must be obeyed in connecting the heater to the hot service water HSW heating system Standard No Standard description SN 06 0320 Thermal systems in buildings Hot wate...

Page 34: ...UP 500 398 350 310 TO 15 IN 500 122 350 310 Fig 1 Heater Dimensions The above supply point version The below supply point version Fig 2 Wiring scheme Explanation 1 Thermostat 2 Thermal fuse non revers...

Page 35: ...en ACHTUNG Wichtiger Hinweis der eingehalten werden muss LESEN SIE BITTE VOR DER INSTALLATION DES WARMWASSERSPEICHERS AUFMERKSAM DIESE ANLEITUNG DURCH Geehrter Kunde Dru stevn z vody Dra ice stroj rna...

Page 36: ...t Die Erw rmung des Brauchwassers auf die empfohlene Temperatur von 60 C betr gt in Abh ngigkeit vom Volumen ca 9 18 und 27 Minuten 3 TECHNISCHE BESCHREIBUNG Der Beh lter des drucklos angeschlossenen...

Page 37: ...muss eine Teilung von 140 mm garantiert sein Die Montageabmessungen sind in der Abb 1 aufgef hrt 7 WASSERINSTALLATION Der Wasserzulauf und auslass ist auf den Rohren des Ger tes mit farbigen Endst ck...

Page 38: ...tsventil wird an den mit dem blauen Ring gekennzeichneten Kaltwasserzulauf montiert Jeder Warmbrauchwasser Druckerw rmer muss mit einem Membran Sicherheitsventil ausgestattet werden Die Nennweite der...

Page 39: ...g vom Wassererw rmer m glichst kurz zu gestalten um die W rmeverluste zu reduzieren Die Wassererw rmer sind mit einem Auslassventil in der Kaltwasserzuleitung um die eventuelle Demontage oder Reparatu...

Page 40: ...den Jegliche Manipulation mit dem Thermostat mit Ausnahme der emperatureinstellung mit dem Einstellknopf ist untersagt S mtliche Eingriffe in die Elektroinstallation die Einstellung und den Austausch...

Page 41: ...n Sie Angaben ber die Typenbezeichnung und Produktionsnummer die Sie am Leistungsschild Ihres Wassererw rmers finden 12 BRANDSCHUTZVORSCHRIFTEN F R DIE INSTALLATION UND NUTZUNG DES WASSERERW RMERS 13...

Page 42: ...nicht vollst ndig abschalten und den Thermostatknopf in die Position bringen Bei solcher Einstellung wird die Wassertemperatur von etwa 9 C aufrechterhalten Wird der Wassererw rmer vom Stromnetz getr...

Page 43: ...ten Bereiche unter Wanne oder Dusche Vorschriften und Richtlinien die beim Anschluss des Ger tes ans System der Warmbrauchwassererw rmung einzuhalten sind Norm Nr Beschreibung der Norm SN 06 0320 W rm...

Page 44: ...50 310 TO 15 IN 500 122 350 310 Abb 1 Abmessungen der Wassererw rmer Ausf hrung oberhalb der Entnahmestelle Ausf hrung unterhalb der Entnahmestelle Abb 2 Elektrisches Schaltungsschema Legende 1 Thermo...

Page 45: ...45 RU 19 RU o Dru stevn z vody Dra ice stroj rna s r o...

Page 46: ...46 RU 1 7 2 60 C 9 18 27 3 5 75 C 13 2 45 C 80...

Page 47: ...4 5 5 75 C 55 C 9 C 6 140 1 7 TO 5 IN UP TO 10 IN UP TO 15 IN UP 5 10 15 0 6 0 6 0 6 7 8 11 2000 2000 2000 10 60 C 9 18 27 1 PE N 230V 50 1 PE N 230V 50 1 PE N 230V 50 IP 24 IP 24 IP 24 0 35 G 0 48 G...

Page 48: ...48 RU SN 06 0830 1 2 3 4 5 6 7 7a 8...

Page 49: ...49 0 6 0 6 0 48 0 7 0 7 0 56 1 1 0 8 RU 20 5...

Page 50: ...50 RU 8 2 230 50 SN 33 2000 4 41 IP 24 9 10 99 C...

Page 51: ...51 RU 477 2001 EKO KOM a s F06020274 11 1 2 3 4 porucha termostatu 12...

Page 52: ...52 RU 13 75 C e 55 C 1 2 3 C 35 C B 45 C A 55 C O 75 C 2 9 C...

Page 53: ...53 RU 14 H O SN 33 2180 SN 33 2000 4 41 SN 33 2000 5 51 SN 33 2000 7 701 H O SN 06 0320 SN 06 0830 SN 73 6660 SN 07 7401 8 SN 06 1010...

Page 54: ...54 RU A B C D E TO 5 UP 400 280 260 265 TO 5 IN 400 155 260 265 TO 10 UP 500 398 350 265 TO 10 IN 500 122 350 265 TO 15 UP 500 398 350 310 TO 15 IN 500 122 350 310 1 2 1 2 3 4 5 L N 5 2013...

Reviews: