Step 1:

 Mounting the Wall-plate

IMPORTANT:

Installation must only be carried out by a 

qualifi ed electrician or heating engineer.

Make sure mains input has a 3 amp fuse.

CAUTION! Before installation, make sure the 

mains supply is switched off!

Option 1: Fitting a new wall-plate

The ideal location is 1.2m above 
fl oor level, with reasonable 
lighting, good access, no 
condensation, no extremes of 
temperature and a supporting 
surface that fully covers the 
back of the unit. Position with 
70mm clearance to the right, 
25mm above and suffi cient room 
to access the securing screws 
underneath. Fix, with terminals 
at the top, either direct to a fl at 
wall using wall plugs and No. 6 x 
1” (25mm) woodscrews, or on a 
fl ush mounting single conduit box 
type UA1 (BS4662) using M3.5 x 
14 bolts. Check the 3A fuse, and 
switch on the mains.

DO NOT use a surface mounting box

 

Battery 

Handling

Batteries, rechargeable or 

not, should not be disposed 

of into ordinary household 

waste. Instead, they must be 

recycled properly to protect 

the environment and cut 

down the waste of precious 

resources.

Your local waste 

management authority can 

supply details concerning the 

proper disposal of batteries. 

In compliance with the EU 

Directive 2006/66/EC, the 

button cell battery located 

on the printed circuit board 

inside the product, can be 

removed at the end of the 

product life, by professional 

personnel only.

Option 2: Using an existing 

industry standard wall-plate

Loosen the securing screws 
on the old programmer and 
unplug it. Check that there is 
70mm clearance to the right of 
the wall-plate and 25mm above 
it. Check the wiring diagram for 
your product model to compare 
terminals and, if necessary, 
change the wiring of the wall-
plate to suit. Now plug the MiTime 
unit into the wall-plate and tighten 
the securing screws.

Check the 3A fuse, and switch on 
the mains.

Mi

Time Programmer Series

RF Packs

Technical Helpline: 0333 7000 622
Website: www.draytoncontrols.co.uk
E-mail: [email protected]

l

 @DraytonControls 

x

 /DraytonControls

EU Design Regs:- 002180638-1/2/3 
Installer Guide 06490194001 Iss 

K

 

INSTALLATION

 Guide

Single Channel: MiTime T710R

Dual Channel: MiTime T720R, T720M

Multi Channel: MiTime T740R, T740M

Step 2:

 Wiring

Connect the wiring as shown above. 

T710R only: Note that the output contacts are voltage-
free, so power needs to be put on to Terminal 1 either 
by linking from Terminal L or from a separate supply 
with a 3A fuse.

Single Channel: 

MiTime T710R

Dual Channel: 

MiTime T720R, T720M

Ch1 Ch2 Ch3 Ch4

Multi Channel: 

MiTime T740R, T740M

Step 3:

 Wireless Thermostats - Checking the batteries

Step 4:

 Signal Strength

Step 5:

 Mounting Options

Step 6:

 Cylinder Sensor (T720M, T740M only)

How do I know when to change 

the batteries?

When the batteries start to run low a battery icon will 
fl ash in the display, to indicate “low battery” during 
this time the MiStat will function normally (see fi g. to 
right). Please replace batteries with 2 x 1.5V IEC LR6 
(AA) Alkaline batteries.  When the battery icon alone 
is shown in the display, the batteries are completely 
exhausted and the MiStat will cease to function 
(see below). Re-activate by replacing the batteries.

The MiStat Room & Cylinder thermostats are pre-bound to the MiTime 
programmer in the factory so they just need to be positioned in the 
best place for wireless communication. To help with this there is a built 
in Signal strength indicator, available in the Installer settings menu on 
the MiTime programmer, as shown. It is recommended that the signal 
strength is Good or Very Good to ensure ongoing communication is 
maintained.

The signal strength can also be seen on the MiStat thermostat. 

To enter signal strength menu

,

S

-

T

S

N

w

o

h

s

 

o

)-

/

+

ll

o

r

c

s

 

n

e

h

,

s

c

e

s

 

5

 .

x

o

r

p

p

a

 r

o

&

 

+

 

s

s

e

r

 


• press ( ) to enter the installer menu, 
• Press +/- until 11 WIRELESS is shown,
• press ( ) to enter, 
• press +/- to show 13 SIG-LEVEL as shown, 

s

s

e

r

p

  

) to see the current signal strength.

How to replace the batteries

Remove the battery covers using a coin. Replace the 
spent batteries with 2 x 1.5V IEC LR6 (AA) Alkaline 
batteries ensuring correct orientation. Replace the 
battery covers pressing fully home.

MiStat

MiStat Rear

Battery Covers:

 

Slide outwards  
to remove

Once the best position has been identifi ed, the MiStat 
should be fi xed to the wall using the wall bracket as 
shown. The cylinder thermostat (T720M, T740M only) 
should be mounted close to the cylinder using the 
wall bracket.

Wiring

Cylinder Thermostat

Cylinder Thermostat Sensor

Locate the external sensor terminal block on the lower 
edge of the MiStat C thermostat, connect a 2-core 
cable, cut to the required length to reach the sensor 
position. Connect to the sensor in the position shown 
and fold wires back through the cable grip & out 
through the cable entry, re-assemble the housing.

Clip the spacer provided 
onto the sensor housing

The sensor should be installed approximately one 
third of the way up the hot water cylinder. With pre-
insulated cylinders, mark the position and size, and 
remove just enough insulation to allow the sensor to fi t 
against the metal of the cylinder in the recess formed.

The plastic covered spring fi xing cable should be cut 
to an un-stretched length of approximately 60-75mm 
(2½”-3”) less than the circumference of the cylinder 
and the hook and eyelet should be screwed intp the 
ends. Stretch the cable round the cylinder, over the 
insulation, and position it in the groove across the 
front of the sensor housing, Engage the hook and 
eyelet.

NB. MiStat can also be positioned using the table 
stand included.

Care should be taken to mount the thermostat in a
position which is not subject to direct sunlight or draughts.
Preferably it should be mounted on an inside wall about 
1.2m (4ft) above the fl oor in a position where it can 
respond to room temperature but away from the direct 
infl uence of radiators or other appliances giving off heat.

MiStat

MiStat

Cable entry

Connect here

NTC Sensor

Cable grip

1/3 cylinder height

Cylinder

Insulation

Fixing cable

Sensor

Sensor

Cylinder

MiTime

MiTime

MiStat

MiTime

IMPORTANT:

Always switch off the mains before removing 

the MiTime programmer – and never fi t it to a 

live wall-plate!

eg.

eg.

It has to be placed in a location where it will be able to 
control the room temperature.

If POOR is displayed, look for a better location 
If NO SIGNAL is displayed, try connecting again with the room unit in 
a different position. To exit, press + & - keys for approx. 5 seconds.  If 
there is no key pressed for 2 minutes, the system will exit the menu.

1.2m

Client

Schneider Electric

File Name

6490194_

K

 Artwork.pdf

Artworker

-

Proof Stage

PRINT

Finished Size

420x297mm

Creative Director

Artwork %

100%

Modification Date

18

/02/1

7

Bleed

3mm

External 

Sensor

401 Southway Drive

Plymouth

PL6 6QT

United Kingdom

Drayton

Drayton

Drayton

Drayton

Drayton

MiStat

Drayton

Reviews: