background image

Models:
13616/13618/13619

Models:
13616/13618/13619

Default Settings
The maximum and minimum setpoints are preset in the factory to
65

o

C and 60

o

C respectively.

06490084001 ISS H

06490084001 ISS H

  Simple Setting or Operating 
 To set the required temperature 

• The display normally shows the current setpoint.
•  To adjust the required temperature, turn the

dial clockwise to increase or anti-clockwise to

decrease, (1 click = 5ºC), the LCD will display

the temperature setpoint as it is being

adjusted  and ‘SET’ will be displayed. After a

few seconds the display will return  to normal

operation and will display the current setpoint.

DHW Cylinder Thermostat

To assist with commissioning or checking the system operation, 

there is a positive OFF setting outside the temperature scale on the 

cylinder thermostat. First adjust the minimum temperature setting

to 40

o

C as described in the user guide, then rotate the dial fully 

anticlockwise for OFF.

‘Boost 1 Hr’

DC RF

DC RF

DC RF 

should now display the ‘E2’ and the RF symbol ‘  ’. If

DC RF

DC RF

DC RF

DC RF

 the 

DC RF

 transmitter unit and sensor can be installed.  

When the sensor is wired to the transmitter unit, the display will 

change after approx. 30 seconds to show the current setpoint and 

‘E2’ will disappear

DC RF

Boost 1 Hr

BOILER

30cm Min

Preferred side of boiler

The range may be affected by

composition/density and number of walls 

between the DiCRF and SCR 

230V a.c. 

230V a.c. 

DC RF 

Heating 

Radio Signal Range:

30m Typically

SCR

 

 

Technical Helpline: +44 (0) 845 130 7722
www.draytoncontrols.co.uk
Email: [email protected]

Digistat 

+

CRF

Digistat 

+

CRF

ON

RECEIVE  / ALARM

OVERRIDE

LEARN

MODE

1

2

Wireless System

Digistat 

+C SCR

Technical Helpline: +44 (0) 845 130 7722
www.draytoncontrols.co.uk
Email: [email protected]

Reviews: