background image

DRAWMER

Dual Channel

Vacuum Tube Compressor

OPERATOR’S MANUAL

CONTENTS

Warranty
Safety Consideration

Chapter 1 - Introduction

Introduction
Installation
Audio Connections
Power Connection

Chapter 2 - Control Description

Control Description
The Quick Setup Procedure

Chapter 3 - General Information

If a fault develops
Contacting Drawmer
Block Diagram

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Summary of Contents for DL221

Page 1: ...ety Consideration Chapter 1 Introduction Introduction Installation Audio Connections Power Connection Chapter 2 Control Description Control Description The Quick Setup Procedure Chapter 3 General Info...

Page 2: ...WARRANTY SHALL BE REPAIR OR REPLACEMENT AS SPECIFIED HEREIN IN NO EVENT WILL DRAWMER ELECTRONICS LTD BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY DE...

Page 3: ...red on both channels is a switchable BIG mode which applies less processing to the fundamental low frequency but still disciplines the upward associated harmonics which if untamed can result in a boom...

Page 4: ...high levels of disturbance such as found close to a TV or radio transmitter we advise that the unit is oper ated in a balanced configuration The screens of the signal cables should be connected to the...

Page 5: ...ltage different to that for which the unit is supplied the following procedure must be carried out by a technically competent person see following diagrams POWER CONNECTION 1 Disconnect the unit from...

Page 6: ...ettings are provided giving various settings The actual attacktime is further modified by the release setting chosen Attack Times 1 2 ms 2 8 msec 3 15 msec 4 25 msec 5 30 msec 6 50 msec Release There...

Page 7: ...istics it closely reflects what is actually being heard though will not respond quickly enough to register short signal peaks VU 10dB VU GR A three position switch adjusts the meters to show either no...

Page 8: ...d All Drawmer products are packaged in specially designed containers for protection If the unit is to be returned the original container must be used If this container is not available then the equipm...

Page 9: ...9 DRAWMER 1968 OPERATOR S MANUAL BLOCK DIAGRAM 1968 ver 01 A 05 05 04...

Reviews: