Draper Access Fit Series Installation & Operation Instructions Download Page 1

Overview -

 Access Fit E and V Components

Section 1 -

 Removing Shipping Brackets  

(Tab-Tensioned, "V" Surfaces only)

 Caution:

  DO NOT remove shipping brackets until product has been mounted and connected to 

power 

(see Section 4 in this document.)

. Also, DO NOT OPERATE SCREEN BEFORE 

removing shipping brackets from screen case.

Section 2 -

 Hanging Screen 

Please Note:

 When locating viewing surface and checking clearance 

for screen operation, ensure that surface is centered in 

the case. 

1. 

Engage each case mounting bracket 

(attached to case)

 with top of 

housing 

(Fig. 2)

 and tighten set screws.

2. 

Screen should be sufficiently supported to withstand vibration.

Please Note:

 A hoisting bracket is included on each end of the case 

to aid in overhead installation.

3. 

Ensure that fasteners are of adequate strength and suitable for the 

mounting surface chosen. Supporting hardware such as chains, 

cables, two 

3

/

8

(9.5 mm)

 rods, etc., must be 

precisely

 vertical.

4. 

Entire bottom of case must be readily accessible after installation is complete.

5. 

Front, back and top of case must be straight—not forced to warp or bow. 

 Caution:

  Screen case and flange are not designed to serve as ceiling support.

6. 

Do not seal unit in ceiling until electrical connections have been made and screen 

operates successfully.

Please Note:

 If case is painted on location, removal of roller/fabric assembly is 

recommended prior to painting. If not removed, slot on bottom  

of case should be shielded to protect viewing surface from paint 

splatters/overspray.

If you have any difficulties installing or servicing your  

Access Fit Screen, call your dealer or Draper, Inc. 

Electrical

Cutout

Tab Tensioning

“V” Dowel

“E” Dowel

Mounting Bracket

Mounting Bracket

Hoisting Bracket

Leveling Brackets

Hoisting Bracket

“E” Free Hanging 

Viewing Surface

“V” Flexible Vinyl 

Viewing Surface

Trim Flange

Shipping Brackets

Attached to Dowel 

and Screen Case

(V Screens Only)

 CAUTION 

Read and understand all warnings (p. 2)  

before beginning installation.

Please Note:

 Shipping brackets must 

remain in place until product has 

been mounted and connected to 

power 

(see Sections 1 and 4 in this 

document)

  Also, DO NOT operate screen 

before removing shipping 

brackets from screen case.

3. Loosen screws     
    and remove the       
    shipping bracket.

1. Remove Fasteners 
    from Bracket Clamps

2. Run the screen
    DOWN to expose 
    the Dowel Screws 

4. Retighten dowel 
    endcap screws.

Figure 1

CASE

MOUNTING

 

BRACKET

7

/

8

"

(22

MM

)

ELECTRICAL

CUTOUT

HOISTING

 

BRACKET

TYPICAL

INSTALLATION

(Brackets may be angled to meet 

 installation requirements.)

CASE

MOUNTING

 

BRACKETS

ALTERNATE

INSTALLATION

CASE

MOUNTING

 

BRACKET

7

/

8

"

(22

MM

)

ELECTRICAL

CUTOUT

HOISTING

 

BRACKET

TYPICAL

INSTALLATION

(Brackets may be angled to meet 

 installation requirements.)

CASE

MOUNTING

 

BRACKETS

ALTERNATE

INSTALLATION

Figure 2

Installation of Case

Please Note:

 Extra brackets 

must be ordered for 

alternate installation.

TOOLS REQUIRED

PENCIL

POWER DRILL

TAPE MEASURE

LEVEL

HARDWARE

 (by others) 

Draper, Inc.  |  411 S. Pearl St. Spiceland, IN 47385 

draperinc.com  |  765.987.7999  |  800.238.7999  

© 2019 All Rights Reserved 

FORM: AccessFit_220V_Inst19

Access FIT E and V 220V

Electric projection screen

INSTRUCTIONS

INSTALLATION & OPERATION

Summary of Contents for Access Fit Series

Page 1: ...nt splatters overspray If you have any difficulties installing or servicing your Access Fit Screen call your dealer or Draper Inc Electrical Cutout Tab Tensioning V Dowel E Dowel Mounting Bracket Moun...

Page 2: ...only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 13 The safety features of the unit should never be disabled bypa...

Page 3: ...visible from bottom of screen housing Please Note If snap ring is provided make sure it engages with motor If retaining clip is provided instead install to lock motor end in place 7 Support idler end...

Page 4: ...usted limit switches stop screen automatically when fully up or fully down 24V CONTROL 3 button UP STOP DOWN switches stop at any point desired operate in any sequence Factory adjusted limit switches...

Page 5: ...l seconds Please Note Move slider switch from down to up in one motion to set limits in same position 4 Set slide switch to higher position Move viewing surface to desired upper limit by holding UP bu...

Page 6: ...There are several knock outs in the screen housing to allow the Leveling Bracket to be adjusted laterally up to 16 40 6cm in either direction Series E Viewing Surface Series V Viewing Surface Standard...

Page 7: ...en Wiring Diagram Back of Wall Switch Back of Wall Switch Please Note 5V DC must be connected to set limits using the wall switch Dry Contacts Back of Wall Switch Back of Wall Switch MOTOR DATA CABLE...

Reviews: