Draper Access FIT E Instructions Installation & Operation Download Page 1

Contents

Overview -

 Components .......................................................................................1

Section 1 -

  Removing Shipping Brackets 

(Tab-Tensioned, "V" Surfaces only)

 .......2

PLEASE READ -

 Safety Information ....................................................................2

Section 2 -

 Hanging Screen .................................................................................3

Section 3 -

 Bottom Access FIT Panel Installation/Removal ..........................3

Section 4 -

 Motorized Roller/Fabric Installation ..............................................4

Section 5 -

 Motorized Roller/Fabric Removal ...................................................4

Section 6 -

 Operation............................................................................................5

Section 7 -

 Tab-Tension Adjustment Procedure ..............................................5

Section 8 -

 Limit Adjustments .............................................................................6

Section 9 -

 Case Length Dimensions .................................................................7

Section 10 -

 Case Width Dimensions .................................................................7

Section 11 -

 Mounting Bracket Dimensions......................................................7

Section 10 -

 Wiring Diagrams: 110-120V Motor and Quiet Motor ..................8

Overview -

 Components

 CAUTION 

Read and understand all warnings 

(Page 2)

 before beginning installation.

Electrical

Cutout

Tab Tensioning

“V” Dowel

“E” Dowel

Mounting Bracket

Mounting Bracket

Hoisting Bracket

Leveling Brackets

Hoisting Bracket

“E” Free Hanging 

Viewing Surface

“V” Flexible Vinyl 

Viewing Surface

Trim Flange

Shipping Brackets Attached  
to Dowel and Screen Case  

(V Screens Only)

Please Note:

 Shipping brackets must remain 

in place until product has been mounted and 

connected to power 

(see Sections 1 and 4 in this 

document.)

 

Also, 

DO NOT

 operate screen before removing 

shipping brackets from screen case.

TOOLS REQUIRED

POWER DRILL

PENCIL

TAPE MEASURE

HARDWARE

 (by others) 

LEVEL

Draper, Inc.  |  411 S. Pearl St. Spiceland, IN 47385 

draperinc.com  |  765.987.7999  |  800.238.7999  

© 2020 All Rights Reserved 

FORM: AccessFit_Inst20

Access FIT E and V

Electric projection screen

INSTRUCTIONS

INSTALLATION & OPERATION

If you have any difficulties installing or servicing your  

Access FIT screen, call your dealer or Draper, Inc. 

Summary of Contents for Access FIT E

Page 1: ...al Cutout Tab Tensioning V Dowel E Dowel Mounting Bracket Mounting Bracket Hoisting Bracket Leveling Brackets Hoisting Bracket E Free Hanging Viewing Surface V Flexible Vinyl Viewing Surface Trim Flan...

Page 2: ...carefully tested to ensure safe and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only...

Page 3: ...steners are of adequate strength and suitable for the mounting surface chosen Supporting hardware such as chains cables two 3 8 9 5 mm rods etc must be precisely vertical 4 Entire bottom of case must...

Page 4: ...knobs are visible from bottom of screen housing Please Note If snap ring is provided make sure it engages with motor If retaining clip is provided instead install to lock motor end in place 7 Support...

Page 5: ...when fully up or fully down Installer should incorporate an all pole disconnect in fixed wiring available with RF or IR remote KEY OPERATED SWITCHING Two key operated switches optionally available wi...

Page 6: ...crew turns 1 2 roller revolution 3 Test by lowering screen Repeat steps 1 2 until desired position is reached To Increase Screen Drop 1 Lower screen to down limit 2 With down switch on turn DOWN I lim...

Page 7: ...of Screen Case Center of Case 3 76mm 13mm 4 124mm 6 164mm 5 130mm 11mm 2 51mm 7 197mm 22mm 16mm 16mm 5 144mm 11mm 1 35mm 7 197mm 6 165mm 3 87mm For minimum length of ceiling cutout subtract 11 4 32mm...

Page 8: ...N Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules FUSE 3 15 AMP 250 VAC 5x20mm To 110 120 VAC Line Red to screen directional Brown to screen directional Yell...