33
5.1.7.
System shut-down
Pressing the button 2.2.2.12 “System shut
-down
”, a system shut
-down takes place.
CAUTION:
No follow-up query occurs. If you shut-down the system while a measurement is on-going,
this data is lost and the measurement must be repeated.
5.1.8.
Leaving the main menu
By pressing the button 2.2.2.13 “Return” yo
u leave the main menu. You return to the user
interface from which you accessed the main menu.
5.2.
Functions of the user interface “Result”
The following functions can only be accessed after taking pictures and the start of an analysis.
5.2.1.
Manual measurement
By pressing the button 2.2.7.6 “Manual” you reach the sub
-menu for a manual measurement
of the woodpile face based on random section heights. Since a return to a photo-optic meas-
urement is not possible, you must confirm the switch to manual measurement in a query.
A manual measurement may be necessary if, for example, the woodpile is too small or if other
woodpile requirements (see Chapter B.2) are not met for an
sScale™ photo
-optic measure-
ment. You can also perform a manual measurement for woodpiles that cannot be reached with
the vehicle. The manual measurement function is based on the section height method and
essentially provides extended computational support for this method. In this way, a manually
measured woodpile can be transferred into the IT structure of the user.
Measure the section heights of the front side of the woodpile according to your specifications
and enter them into the mask using the keyboard at the upper right edge of the picture.
Measure the length of the woodpile and enter it using t
he button 2.2.9.5 “Length”. Once you
have determined the mean diameter, you can enter this via the button 2.2.9.6 “Diameter”.
You can enter the number of logs in the woodpile using the button 2.2.9.7 “Quantity”.
The mean diameter and number of logs are not mandatory fields and can be left blank.
After entering all the measured quantities, complete the manual measurement by pressing the
button 2.2.9.8 “Done” and return to the “Result” user interface.
For documentation purposes, a single picture of the picture sequence is saved with the data
record.
NOTE:
Avoid switching to a manual measurement if there is a successful analysis. In rare cases, this
can lead to a fault in the system.
CAUTION:
A manual measurement is non-conformity-rated according to Measurement and Verification
Act!
Summary of Contents for sScale
Page 2: ......
Page 6: ......
Page 9: ...3 Figure 3 Schematic structure of the sScale ...
Page 26: ...20 Figure 9 Automatic generated polygonal course insufficient optimisation ...
Page 27: ...21 Figure 10 Edited polygonal course excessive optimisation ...
Page 28: ...22 Figure 11 Edited polygonal course adequate optimisation ...