F1

F2

F3

F4

Figure 1

F4 - Mode Switch
Sets the type of channel, CATV or Broadcast
TV (“BC TV”).  The "+100" position of the switch
sets a leading “1” for CATV channels 100
through 135.  See also Item F3 for setting the
channel number.

For example:

For example:

Setting for CATV

Setting for CATV

channel "124"-

channel "75"-

F1 - POWER/ERROR Indicator
Lights when the unit is connected to the
required source of DC power via the rear panel
DC INPUT connector.  A flashing condition
indicates an invalid channel setting or other
conditions that would cause the unit to operate
on an invalid channel.  The RF output is
switched off for flashing (ERROR) conditions.

F2 - SIGNAL Indicator
Lights when a signal is present.

F3 - Channel Number Switch
Sets the desired operating channel for standard
CATV channels 02 through 135 or Broadcast
TV channels 02 through 69.  See also Item F4
which sets the type of channel (CATV or
Broadcast TV) and sets the leading “1” for
CATV channels 100 through 135.

DDC864 DIGITAL DOWNCONVERTER          1

TM

12 POSITION RACK MOUNT                                                                       POWER SUPPLY

DDC864

DOWNCONVERTER

TM is a trademark of the R.L. Drake Company

   is a registered trademark of the R.L. Drake Company

  Copyright 2006 R.L. Drake Company          P/N: 3852391A-1-2006       Printed in the U.S.A.

The R.L. Drake DDC864 is a low noise
downconverter designed for translating
digital signals from their off-air or CATV
channel to a 44 MHz IF output.  The output of
the DDC864 can be connected to a DUC
series upconverter to place the digital signal
on a new output channel.

When the DDC864 is used with the DUC550
or DUC860, all input/output channel
combinations are usable except "on
channel" conversions.

When the DDC864 is used with the DUC864,
"on channel" conversions, (the same input
channel on the DCC and output channel on
the DUC) are acceptable.

The  DDC864 is optimized for use with ATSC
8VSB modulation in a 6 MHz wide channel
assignment. The passband is designed for
optimized operation with 8VSB signals in an
adjacent channel environment. For translation
of QAM signals, the Drake model QQP860 is
preferred for this task.

The DDC864 provides low noise figure and low
phase noise as well as a flat passband to
minimize signal deterioration.

2

5

7

5

CATV

+100

CATV

CATV

+100

CATV

BC

TV

TV

BC

 

DDC864

PWR/

ERROR

CATV

+100

BC

TV

CATV

2

5

SIGNAL

 

PS8

POWER SUPPLY

DUC864

GAIN

PWR/

ERROR

CATV

+100

BC

TV

CATV

2

1

DDC864

PWR/

ERROR

CATV

+100

BC

TV

CATV

2

5

SIGNAL

DUC864

GAIN

PWR/
ERROR

CATV

+100

BC
TV

CATV

2

1

DDC864

PWR/

ERROR

CATV

+100

BC
TV

CATV

2

5

SIGNAL

DUC864

GAIN

PWR/

ERROR

CATV

+100

BC
TV

CATV

2

1

DDC864

PWR/

ERROR

CATV

+100

BC

TV

CATV

2

5

SIGNAL

DUC864

GAIN

PWR/

ERROR

CATV

+100

BC

TV

CATV

2

1

DDC864

PWR/

ERROR

CATV

+100

BC
TV

CATV

2

5

SIGNAL

 

CATV

TV

BC

+100

CATV

DDC864

25

CATV

TV

BC

+100

CATV

ERROR

PWR/

GAIN

DUC864

35

CATV

TV

BC

+100

CATV

ERROR

PWR/

GAIN

DUC864

28

CATV

TV

BC

+100

CATV

DDC864

25

DRMM4

SIGNAL

ERROR

PWR/

SIGNAL

ERROR

PWR/

 

Summary of Contents for DDC864

Page 1: ...gnals from their off air or CATV channel to a 44 MHz IF output The output of the DDC864 can be connected to a DUC series upconverter to place the digital signal on a new output channel When the DDC864 is used with the DUC550 or DUC860 all input output channel combinations are usable except on channel conversions When the DDC864 is used with the DUC864 on channel conversions the same input channel ...

Page 2: ... to power all units Figure 3 ACPOWER CONNECTOR RACK MOUNTING Adequate ventilation is very important in multichannel installations Units should be spaced apart vertically by at least 1 75 wherever possible and some air movement is mandatory in enclosed rack cabinets Excessive heat will shorten component life and performance will be degraded without proper cooling POWER SUPPLY POWER 12 V GND 5 V IF ...

Page 3: ...IA NCTA Numeric Equivalent 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 Frequency in MHz 327 333 339 345 351 357 363 369 375 381 387 393 399 405 411 417 423 429 435 441 447 453 459 465 471 477 483 489 495 501 507 513 519 525 531 537 543 549 555 561 567 573 579 585 591 6 BROADCAST TV CHANNEL INPUT FREQUENCIES ...

Page 4: ...ntity of the seller and the approximate date of purchase and c A detailed description of the problem including details on the electrical connection to associated equipment and the list of such equipment 3 3 3 3 3 Deliver the product to the R L DRAKE COMPANY or the nearest authorized service facility or ship the same in its original container or equivalent fully insured and shipping charges prepaid...

Page 5: ...or expenses Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty shall be construed under the laws of Ohio 8 ...

Page 6: ...re 1 F4 Mode Switch Sets the type of channel CATV or Broadcast TV BC TV The 100 position of the switch sets a leading 1 for CATV channels 100 through 135 See also Item F3 for setting the channel number For example For example Setting for CATV Setting for CATV channel 124 channel 75 F1 POWER ERROR Indicator Lights when the unit is connected to the required source of DC power via the rear panel DC I...

Page 7: ...9 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Center of Channel Frequency MHz UHFBROADCASTCHANNELS Channel Number REAR PANEL CONNECTIONS 3 Figure 2 R1 R2 R3 R1 IF OUTPUT Connector This is the 44 MHz IF output The level is 30 dBmV R2 DC INPUT Connector This 3 pin connector Male accepts the appr...

Page 8: ...5 351 357 363 369 375 381 387 393 399 405 411 417 423 429 435 441 447 453 459 465 471 477 483 489 495 501 507 513 519 525 531 537 543 549 555 561 567 573 579 585 591 4 INSTALLATION CONNECTIONS AND CONTROLS All connections to and from each upconverter are made through the rear panel DESCRIPTION Figure 3 shows a typical installation utilizing the Drake DRMM12 rack with 4 DDC864 downconverters and 4 ...

Reviews: