DRAKE DA100032 Installation Manual Download Page 1

®

Distribution Amplifiers

1

DESCRIPTION

The R.L. DRAKE models DA100042, DA100032, DA8642, DA8632,
DA7543, and DA7533, are broadband distribution amplifiers designed for
indoor use in both residential and commercial buildings where RF signal
distribution in the frequency range of 49 to 1000 MHz is required. Each
model provides a very low distortion signal for a cable TV “drop”, the output
of an SMATV headend, or a small CATV headend. The amps are suitable
for both analog and digital - ATSC or QAM, amplification. The Gain and
Slope controls both have a range of 10 dB minimum and operate between
the preamp hybrid and the output hybrid to maintain a low noise figure over
a wide range of gain and slope settings. Double-sided, plated through hole,
glass epoxy, printed circuit boards, and SMT are used for low losses and
maximum reliability.

All models include a 20 dB gain integrated active return path amplifier,
and can provide a nominal unity gain passive return or no return path by
selection with internal jumpers.

Input and output test connectors are provided for convenient monitoring of
the signal path. The amplifier circuitry is designed for maximum stability,
low distortion, low noise figure, and is protected in a rugged aluminum
housing.

The unit operates from a nominal 26 VAC provided by the supplied
120 VAC, 60 Hz input AC Adapter.

Input equalizer and fixed attenuator options are available.

4) If the power transformer is to be wall mounted, install the included
bracket as shown. Then mount transformer to the wall.

5)

Connect input and output cables to the amplifier.

6)

Plug the power transformer line cord into a 120 VAC/60 Hz

power source.

7)

Preset slope control fully clockwise.

8)

While monitoring the output levels at the Output -30 dB test port, adjust

the Gain control for desired output at the high end of the band. Then
monitor the lowest channel and adjust slope control to equalize this channel
to the desired level (usually equal to but not higher than the high end of the
band). Since there can be a slight interaction between the gain settings, it
is advised to repeat this step a few times to ensure the desired levels are
attained.

NOTE:

The -30 dB input and output test ports can be used to monitor input

and output levels. These are only accurate when the load is connected to
the amplifier output and power is on.

INSTALLATION
1)

Unpack the distribution amplifier and AC adapter.

2)

Mount the amplifier in the desired location, using the four mounting screw

holes on the sides of the amplifier. Vertical mounting on a wall with the
output end up is recommended for best ventilation and the coolest operation.

3)

Route the power cable as needed to the power transformer. The cable

can be pushed between fins of the heat sink on the bottom of the amplifier.
Connect the power cable to the screw terminals on the power transformer.

OUT

SCREW HOLES FOR
WALL MOUNTING
(2 each side)

IN

TRANSFORMER

SCREWS FOR FASTEN-
ING
MOUNTING BRACKET
TO TRANSFORMER CASE

WALL MOUNTING HOLES
OF MOUNTING BRACKET

Summary of Contents for DA100032

Page 1: ...If the power transformer is to be wall mounted install the included bracket as shown Then mount transformer to the wall 5 Connect input and output cables to the amplifier 6 Plug the power transformer line cord into a 120 VAC 60 Hz power source 7 Preset slope control fully clockwise 8 While monitoring the output levels at the Output 30 dB test port adjust the Gain control for desired output at the ...

Page 2: ...the return amplifier When selecting the active return Jumper J2 must be installed If using the passive return or no return remove Jumper J2 INTERNAL JUMPER SETTINGS 1 Unplug amp from the AC power source 2 Remove top cover by loosening but not removing the 12 top cover screws Slide the top cover so the screws will slip through the larger screw hole openings then remove top cover POWER LED B JUMPER ...

Page 3: ...ng the distribution amp are sloped then the highest frequency channels can be set to higher output levels that shown below for a flat input In general install a fixed input attenuator if required to set the highest frequency channels in the input to within the optimum range Then set the amplifier gain to achieve the desired output level not to exceed the maximum output level listed in the chart be...

Page 4: ... Drake service facility will provide free of charge both parts and labor necessary to correct defects in material and workmanship At its option R L DRAKE LLC may replace a defective unit To obtain such warranty service the original purchaser must 1 Retain invoice or original proof of purchase to establish the start of the warranty period 2 Notify R L DRAKE LLC or the nearest authorized service fac...

Page 5: ...ROGRAMMABLE REVERSE STEP ATTENUATOR SETTINGS There are four internal jumpers used to set the programmable reverse attenuation Each jumper controls an attenuator The four attenuator values are 2 dB 4 dB 8 dB and 16 dB The total attenuation is the sum of any attenuators that have jumpers set to the IN setting When a jumper is set to the OUT setting that attenuator is out of the circuit and is effect...

Reviews: