OWNER’S MANUAL

ProXtrak

LIQUID EXTRACTOR

LIVR-08

 - PRINTED IN CANADA (05-18)

Cleaning Systems

Summary of Contents for ProXtrak DF2P552

Page 1: ...OWNER S MANUAL ProXtrak LIQUID EXTRACTOR LIVR 08 PRINTED IN CANADA 05 18 Cleaning Systems ...

Page 2: ...cleaner creates suction Keep hair face fingers all body parts and loose clothing away from any openings Never plug in a unit designed to operate with a current of 120V in a 230V outlet and vice versa If the power cord is damaged it must be replaced by a special cord available from the authorized local dealer distributor Do not use extension cords or outlets with inadequate current carry capacity N...

Page 3: ...lation process If you have any concerns or problems you may encounter please contact the nearest retailer The unit s profile will be required To fill in the Drainvac product registration form go to www drainvac com client support register your drainvac Model Serial number Retailer name Date of purchase Date of the last maintenance INTRODUCTION REGISTRATION This information is found on a metal tag ...

Page 4: ...E The sensitivity of the electrodes can be modified by the printed circuit board See Annex for more information The rubber hand is closed The water comes into contact with the electrodes The unit can be placed on top of a floor drain shower or outside where permitted The ProXtrak was designed with a purposely moulded bottom for it to sit on the toilet and to vacuum liquids The tank never has to be...

Page 5: ...3 5 8 imp gal 36 L 15 imp gal min 68 L min 15 dia x 43 38 dia x 95 DV2P57 700 125 150 68 13 DV2P552 Truck mount 3 Truck mount MODELS AIR WATTS mmH2O m3 h DECIBELS AMPS CAPACITY FLOW SIZE in cm DF2P56 2 x 465 3683 415 72 2 x 7 8 imp gal 36 L 15 imp gal min 68 L min 15 dia x 43 38 dia x 95 DF2P57 700 3605 315 68 7 DF2P552 Truck mount 2 Truck mount You have purchased one of the following models Ident...

Page 6: ...de any motor As illustrated on pages 6 and 7 of this manual the Automatik system evacuates wastewater automatically after approximately 10 to 15 minutes Keep in mind that as long as the system is operating water keeps flowing and the unit eventually fills up The membrane allows you to adjust the time lapse during which the unit deactivates and empty its contents The unit also clears out the wastew...

Page 7: ...not immerge the hose completely Allow some air in Let unit run for 1 to 2 minutes to dry out the accessories and the hose Stop unit and leave it in position to let it drip After storing the accessories and the hose remove the unit To avoid dripping on the floor carry the unit horizontally by tilting it towards you ELECTRICAL POWER SUPPLY The liquid extractor is a plug in type Some have up to two 2...

Page 8: ...MAINTENANCE PROCEDURES Each system requires a minimum maintenance without any exception MOTOR BRUSHES Beyond the occasional external cleaning we recommend that you inspect your motor brushes after 500 hours of use to check how worn they are and have them replaced if necessary When the time comes contact your retailer or distributor for this maintenance procedure Take note that the motor brushes ar...

Page 9: ... information contact your municipal waste management department If you wish to speak with a customer service representative please contact your supplier dealer To find a retailer near you please visit our website www drainvac com retailers html All presented units respect the European directive RoHS which limits the usage of six dangerous substances Drainvac International 150 Brunet Street Mont St...

Page 10: ......

Page 11: ... J21 RL1 RL2 ACC2 L2 L L1 N INT 240V NA 240V NA 120V ELECTRODE VALVE FUSE LINE FUSIBLE ANNEXE II CIRC14R5NA1 DIAGRAMME DE CONNEXIONS DV2P57 DF2P57 ANNEX II CIRC14R5NA1 CONNECTION DIAGRAM DV2P57 DF2P57 P1 LS1 LS2 R28 R21 R12 R53 R54 R51 R52 SW1 J2 D3 C1 C2 C3 J1 J6 Q9 T1 U2 F3 F2 F1 C9 J5 U3 Q7 Q10 Q11 Q12 Q24 Q13 Q20 Q21 R46 R50 R43 R47 Q23 Q22 C23 C22 R45 R49 R44 R48 Q4 Q8 U1 D2 D5 Q3 Q2 Q18 Q17 ...

Page 12: ...N INT 240V NA 240V NA 120V ELECTRODE N1 N2 L2 HOUR METER COMPTEUR HORAIRE FUSE LINE FUSIBLE L1 ANNEXE III CIRC14R5NA1 DIAGRAMME DE CONNEXIONS 108 120 VOLTS DV2P54 DV2P56 ANNEX III CIRC14R5NA1 CONNECTION DIAGRAM 108 120 VOLTS DV2P54 DV2P56 P1 LS1 LS2 R28 R21 R12 R53 R54 R51 R52 SW1 J2 D3 C1 C2 C3 J1 J6 Q9 T1 U2 F3 F2 F1 C9 J5 U3 Q7 Q10 Q11 Q12 Q24 Q13 Q20 Q21 R46 R50 R43 R47 Q23 Q22 C23 C22 R45 R49...