DragonEye Compact Speed LIDAR Operator Manual
DragonEye Technology, LLC / Doc. 30666 Rev. 03
21
Advanced Controls and Modes
Daily Test Initiation
Press
to enter the system menu options. “Self Test” is
displayed as the first menu option. Press
to initiate the Daily
Test sequence. The operator will be prompted to complete each test
required. All critical internal timing electronics and software
components are checked. Also, all display components are
illuminated to allow the user to verify proper operation. A pass or
fail indication is given at the end of the self-test. A “pass” indication
then returns the operator to the current mode of operation, while a
“fail” indication will halt operation indicating the need for service.
Weather Modes
Press the
button, and then use the up/down arrows
to select “Weather”. Press Enter
to select “Weather”
then use the up/down arrows to select “Normal” or “Poor”. Press
the Enter button
to confirm your choice and exit back to your
current mode of operation. The weather modes function as
described below:
Normal Weather Mode
In Normal Mode, the LIDAR has no additional restrictions placed
upon the minimum distance at which a target can be acquired
(besides the normal minimum range specification). If rain, snow, fog
or other obstacles are present in the line of sight to the target, it is
MENU
MODE
ENTER
MENU
MODE
ENTER
MODE