Fault warm-up 1
This function is used to set operation of the fault relay during
warm-up 1. It can be configured to be active permanently (static)
or 1 second active and 9 seconds not active (dynamic).
Relay test
These functions change the status of a relay and LED for test
purposes (e.g. to check the function of alarm devices connected
to the relay) and the symbol [
] is displayed. After exiting this
function, the status of the relay and LED will automatically return
to their previous status.
Set alarm A1
1. Select
Settings > Instrument > Alarm > Set alarm A1
and confirm.
2. Select
Enable
or
Disable
and confirm.
Set alarm A2
1. Select
Settings > Instrument > Alarm > Set alarm A2
and confirm.
2. Select
Enable
or
Disable
and confirm.
Set fault
1. Select
Settings > Instrument > Alarm > Set fault
and
confirm.
2. Select
Enable
or
Disable
and confirm.
5.8.2
Passwords
These functions change the passwords for calibration (zero
and span calibration) and settings (access to all configuration
parameters).
1. Select
Settings > Instrument > Passwords > Calibration
PWD
or
Settings PWD
and confirm.
2. Select the line for editing the password and confirm.
3. Set the password and confirm.
The setting for the password is displayed.
4. Select
Confirm
and confirm with [OK].
5.8.3
Date and time
1. Select
Settings > Instrument > Date and time
and
confirm.
2. Select the line for editing the date or time and confirm.
3. Set each digit and confirm.
4. Select
Confirm
and confirm with [OK].
5.8.4
Language
1. Select
Settings > Instrument > Language
and confirm.
2. Select the language from the list and confirm.
NOTICE
For safe operation:
The relays must be set to “Normally energized” and
the A2 alarm (main alarm) must be set to “latching”
and “not acknowledgeable” or “pre-
acknowledgeable”.
The A1 alarm (pre alarm) may only be set to
“acknowledgeable” if it is used for triggering an
acoustic alarm device.
NOTICE
When the relays are activated, alarm devices will be
switched on.
NOTICE
If the function is activated, the fault relay is asserted and
the 4 to 20 mA interface is set to the fault current. The
yellow LED is lit, the symbol for maintenance is
shown [
].
i
i
i
i
i
i
NOTICE
The correct date and time settings are important for
many functions.
i
i
Summary of Contents for Polytron 8100
Page 2: ......
Page 3: ...1 5 4 3 2 5 1 4 3 10 7 8 9 2 6 3 4 5 2 1 3 9 5 2 1 14 13 3 4 5 6 7 8 14 2 11 12 15 A B C D E...
Page 223: ...Dr ger Polytron 8100 223 4 5 2 4 5 3 OK OK 4 5 4 OK 5 OK 3 3 2 2...
Page 250: ...250 Polytron 8100 Additional Approvals A 3 Control Drawings...
Page 252: ...252 Polytron 8100 Additional Approvals A 4 Declaration of conformity...
Page 253: ......