![Dräger Infinity Delta Instructions For Use Manual Download Page 159](http://html.mh-extra.com/html/drager/infinity-delta/infinity-delta_instructions-for-use-manual_2526779159.webp)
ECG S
ETUP
M
ENU
VF8
D
ELTA
/D
ELTA
XL/K
APPA
8-19
The
Lead Setup
submenu
This submenu allows you to configure the following functions.
ECG
Channels
Determines the number and
format of displayed ECG
waveforms
NOTE
:
The TruST 12-lead
derived leads cannot be
displayed as ECG1 or ECG2.
They can only be displayed in
the Show All Leads view.
•
ECG1
– displays the primary ECG signal.
•
ECG1 & 2
– displays two ECG signals.
•
ECG1 & 2 & 3
– displays three ECG channels.
•
Cascade
– cascades ECG1 data into the
second channel.
Channel 1
Channel 2
Channel 3
Selects leads for continuous
display in ECG channel(s) on
the main screen.
Channel 1, Channel 2, Channel 3
(scroll
through the list of available leads and click to
select for display).
NOTE
: The
Cable Type
setting determines the
list of available leads for selection.
12 Lead
Position
Configures monitor for Standard
or Frank 12-lead monitoring (see
page 8-13 for more information).
• Standard
– configures the monitor for
standard 12-lead monitoring.
• Frank
– configures the monitor for Frank
12-lead format.
Menu
Selection
Description
Available Settings
Summary of Contents for Infinity Delta
Page 76: ...2 26 DELTA DELTA XL KAPPA VF8 2 MONITOR SETUP This page intentionally left blank ...
Page 94: ...3 18 DELTA DELTA XL KAPPA VF8 3 NETWORK APPLICATIONS This page intentionally left blank ...
Page 118: ...5 16 DELTA DELTA XL KAPPA VF8 5 ALARMS This page intentionally left blank ...
Page 140: ...7 14 DELTA DELTA XL KAPPA VF8 7 RECORDINGS This page intentionally left blank ...
Page 166: ...8 26 DELTA DELTA XL KAPPA VF8 8 ECG AND HEART RATE This page intentionally left blank ...
Page 176: ...9 10 DELTA DELTA XL KAPPA VF8 9 ARRHYTHMIA MONITORING This page intentionally left blank ...
Page 188: ...10 12 DELTA DELTA XL KAPPA VF8 10 ST MONITORING This page intentionally left blank ...
Page 198: ...11 10 DELTA DELTA XL KAPPA VF8 11 EEG MONITORING This page intentionally left blank ...
Page 218: ...12 20 DELTA DELTA XL KAPPA VF8 12 RESPIRATION This page intentionally left blank ...
Page 256: ...14 22 DELTA DELTA XL KAPPA VF8 14 INVASIVE BLOOD PRESSURE This page intentionally left blank ...
Page 272: ...15 16 DELTA DELTA XL KAPPA VF8 15 CARDIAC OUTPUT C O This page intentionally left blank ...
Page 290: ...16 18 DELTA DELTA XL KAPPA VF8 16 CALCULATIONS This page intentionally left blank ...
Page 372: ...21 14 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS T NEONATAL FLOW SENSOR ...
Page 384: ...21 26 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS This page intentionally left blank ...
Page 526: ...A 6 DELTA DELTA XL KAPPA VF8 A GLOSSARY This page intentionally left blank ...
Page 584: ...B 58 DELTA DELTA XL KAPPA VF8 B TECHNICAL DATA This page intentionally left blank ...
Page 613: ...POD COMMUNICATION VF8 DELTA DELTA XL KAPPA C 29 ...