Bodyguard

®

 1500

PASS (Personal Alert Safety System)

Instructions for Use

i

Bodyguard

®

 is a registered trademark of Dräger

3361121 (A3-D-P) Page 1 of 2

1

For your safety

1.1

General safety statements

● Before using this product, carefully read the instructions for use.

● Strictly follow the instructions for use. The user must fully understand

and  strictly  observe  the  instructions.  Use  the  product  only  for  the

purposes specified in the Intended Use section of this document.

● Do  not  dispose  of  the  instructions  for  use.  Ensure  that  they  are

retained and appropriately used by the product user.

● Only  fully  trained  and  competent  users  are  permitted  to  use  this

product.

● Comply  with  all  local  and  national  rules  and  regulations  associated

with this product.

● Only trained and competent personnel are permitted to inspect, repair

and  service  the  product.  Dräger  recommends  a  Dräger  service

contract for all maintenance activities and that all repairs are carried

out by Dräger.

● Use only genuine Dräger spare parts and accessories, or the proper

functioning of the product may be impaired.

● Do  not  use  a  faulty  or  incomplete  product,  and  do  not  modify  the

product.

● Notify Dräger in the event of any component fault or failure.

1.2

Definitions of alert icons

Alert  icons  are  used  in this  document  to  provide  and  highlight  text  that

requires a greater awareness by the user. A definition of the meaning of

each icon is as follows:

WARNING

Indicates a potentially hazardous situation which, if not avoided,

could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided,

could  result  in  physical  injury  or  damage  to  the  product  or

environment. It may also be used to alert against unsafe practices.

NOTICE

Indicates additional information on how to use the product.

2

Description

2.1

Product overview

The Bodyguard

®

1500 is a battery powered Personal Alert Safety System that

provides audible and visible alarm signals. Audible signals are loud and easily

recognized  with  varying  alarm  patterns  to  distinguish  between  different

warning conditions. The alarm is from an electronic sounder that uses the tally

slots as amplification chambers to provide clear and loud alarm signals.

Visible signals are provided by red, blue, green and amber LEDs on the casing.

During use the unit displays a flashing green LED that indicates active mode,

and pulsing blue LEDs that are used as a visual identification signal (or buddy-

beacon) for fellow team members.

The unit is configured as either a button version or a button version with a

tally cancel. The main difference between the version types is the alarm

cancelling method:

● Button version – the buttons on the side of the unit are used to arm and

cancel automatic alarms (a tally is not supplied with button versions).

● Button version (with tally cancel) – the buttons on the side of the unit

are used to arm and cancel automatic alarms. The tally is intended for

use  during maintenance.  Inserting the tally  prevents audible alarms

from sounding during maintenance.

The unit is fixed on to the outside of protective clothing or equipment using

one  of three  different  fixing  options. The standard fixing  is a  low-profile

harness clamp. An alternative (supplied with the unit) is an adaptor which

attaches  the  unit  to  a  universal  accessory  clip.  An  optional  alternative

(supplied as an accessory) is a crocodile clip with combined wire D-ring.

2.1.1

Distress alarms

The main function of the unit is to provide automatic and manual distress

alarms. The automatic distress alarm uses an internal motion sensor and

timer to measure the time that wearer has been motionless, in order  to

indicate that the wearer may be unconscious or trapped. The automatic

distress  alarm  activates  a  pre-alert  ( )  and  a  full  alarm  (

)  at

predetermined timed intervals when the wearer does not move in excess

of normal breathing movement. The manual alarm is operated by pressing

the yellow button ( ), to allow the wearer to signal for help or attention.

2.1.2

Thermal exposure alarm

Protective  clothing  insulates  the  wearer  from  the  thermal  environment,

making it difficult to appreciate the level of heat or thermal exposure. The

Bodyguard

®

1500 includes a thermal sensor that monitors exposure and

starts a timer at a set start temperature (the default start temperature is

40 °C). Once the timer has started, two thermal exposure alarms activate

at time-weighted temperature thresholds. The alarms warn the user of a

relatively long period of exposure to slightly elevated temperatures, or of a

short period of exposure in high temperature situations.

The  thermal  sensor  can  be  disabled  or  the  start  temperature  can  be

configured  to  meet  the  individual  operational  needs  of  the  user  using

Dräger PC Link (see Section 2.1.3).

2.1.3

Radio frequency link

The radio frequency (RF) link allows one or more units to be paired with a

Dräger Bodyguard

®

 TX Gauge on a breathing apparatus. When paired with

a TX Gauge, the Bodyguard

®

1500 will automatically switch on if it is within

1 m of the paired TX Gauge when the gauge is switched on. The paired

Bodyguard

®

1500 cannot be switched off until the TX Gauge is switched

off. See Section 3.4.3 for details of pairing the unit.

The  Bodyguard

®

1500  is  equipped  with  radio  frequency  communication

circuitry that enables wireless reading and reprogramming of the unit. This

information includes unit identity, a record of events (datalog), parameter

maintenance  and  firmware  reprogramming. The parameter  settings  that

are configurable include enabling/disabling of alarms, motion alarm times,

alarm sounds, etc. The alarm parameters described in this document are

the default settings for the unit.

Reprogramming  the  unit  requires  Dräger  PC  Link.  Contact  Dräger  for

details.

!

!

i

i

2.2

Intended use

The Bodyguard

®

1500 is intended for use by firefighters, other emergency

services, and  industrial users  engaged in fire fighting, rescue  and other

hazardous duties with a TX Gauge. The unit provides clear, distinct and

easily recognized alarm signals that indicate wearer immobilization, a call

for  help  or  attention,  or  warn  of  excessive  thermal  exposure.  Distress

alarms can be used by rescue teams to pinpoint the position of the source

of the alarm. The unit may be used as a stand-alone device.

2.2.1

Limitations on use

A  limitation  of  the  automatic  distress  alarm  is  that  the  motion  sensor

detects movement or vibration to which the wearer is subjected, and may

not activate if the wearer is motionless on a moving platform (for example,

on moving or vibrating machinery).

Special conditions for safe use:

The  recessed  label  is  made  from  aluminium  foil.  The  end  user  shall

exercise care to ensure that the label is not subject to impact or abrasion

during use as this may cause incendive sparks.

The metal fixing clamp is an isolated conductive part with a capacitance of

6 pF, exceeding the values permitted by Table 9 of EN60079-0:2012 for

Group II equipment. This should be taken into consideration by the user as

an electrostatic discharge risk in determining suitability for use.

2.3

Approvals

The  European  standards,  guidelines,  and  directives  according  to  which

this product is approved are specified in the declaration of conformity (see

declaration of conformity or www.draeger.com/product-certificates).

2.4

Marking and symbols

CAUTION

Do  not  use  marker  pens  or  apply  paint,  and  do  not  scratch  or

engrave  the  unit,  as  this  may  damage  the  unit  or  invalidate

approvals. It is recommended that any personal marking of the unit

is made using adhesive labels.

BRXX-1234

Dräger serial number
Left-hand button and active LED
Right-hand button
Low battery LED
Radio frequency (RF) communication symbol

!

3

Use

CAUTION

The  tally  from  a  Bodyguard

®

1500  with  a  tally  cancel  must  be

removed before the automatic distress alarms will activate. Ensure

that the tally is removed before commencing operations.

3.1

Preparation for use

3.1.1

Initial assembly

The rear  cover  and batteries  are supplied  loose (unfitted) with  the  unit.

Install them before first use (see Section 3.4.2).

If the unit is supplied with the crocodile clip accessory, fit the clip as follows:

1. Remove the harness clamp from the rear cover (Fig 2).

2. Install the batteries and rear cover as normal (see Section 3.4.2).

3. Connect the crocodile clip accessory (Fig 3). Gently tighten (nip up)

the screw using a T10 driver. Dräger recommend a torque of 0.8 Nm

(0.6 lbf ft) – do not

 

over tighten.

If fitting the unit to a universal accessory clip, fit the adaptor as follows:

1. Install the batteries and rear cover as normal (see Section 3.4.2).

2. Fit the universal accessory clip adaptor and secure in place with the

harness clamp (Fig 4).

NOTICE

Only secure the universal accessory clip adaptor to the unit with

the harness clamp. Do not use a screw, such as the one supplied

with the crocodile clip accessory.

3.1.2

Preparation for use

1. Install the batteries if necessary (see Section 3.4.2).

2. Pair unit with a TX Gauge if necessary (see Section 3.4.3).

3. Carry out a functional test (see Section 3.4.1).

WARNING

Fitting the unit inside protective clothing would insulate the thermal

sensor  from  the  thermal  environment  and  delay  alarm activation,

risking  over  exposure  to  high  temperatures.  Fix  the

Bodyguard

®

1500 outside any protective  clothing  and ensure that

the sensor is clear of obstructions.

NOTICE

The optimum fitting positions are on the front of the wearer at the

shoulder (Fig 5 and Fig 6) or waist (Fig 7). The shoulder position may

expose  the  thermal  sensor  to  slightly  higher  temperatures,  and  is

recommended for fire fighting operations.
The shoulder fitting position allows the unit to be paired with a TX

Gauge while wearing a breathing apparatus. See Section 3.4.3 for

details of pairing the unit.

4. Fit  the  unit  to  a  breathing  apparatus  harness  strap  or  to  protective

clothing.

3.2

During use

3.2.1

Switching the unit on and off

To switch on the unit:

● If the unit is being used as a stand-alone device press the left-hand

button.

● If the unit is paired with a TX Gauge, open the breathing apparatus

cylinder valve. The unit will switch on automatically.

To switch off the unit:

● If the unit is being used as a stand-alone device simultaneously press

the left-hand and right-hand buttons.

● If the unit is paired with a TX Gauge, switch off the TX Gauge (see the

TX Gauge instructions for use) and then simultaneously press the left-

hand and right-hand buttons.

3.2.2

Operating modes and functions

Use  and  activation  of  alarms,  and  any  evacuation  and  recovery

procedures,  should  be  in  line  with  existing  command  and  control

procedures.

Sleep  mode

  –  When  the  unit  is  switched  off  it  enters  a  sleep  mode

(awaiting an activation signal). The automatic alarms are disabled and all

LEDs  are  off.  The  manual  distress  alarm  can  be  activated  from  sleep

mode.

Active mode

 – When the unit is switched on, and passes the self check,

a start-up signal occurs (four beeps, and brief illumination of all LEDs) and

then the unit enters the active mode indicated by a flashing green LED

(every  second).  Automatic  alarms  are  enabled  and  the  buddy-beacon

signal is on.

Error alert

 – If the unit fails the self check during start-up, or if a hardware

failure occurs during use, the error alert activates (five beeps plus high-

frequency flash of the amber LED).

Pre-alert

  ( )  –  No  movement  sensed  for  21–25 seconds.  Activates  a

repeating,  increasing-volume,  triple-beep  alarm  tone  accompanied  by

alternating red and blue LEDs.

Automatic distress alarm

 (

) – No movement sensed for 8 seconds

of pre-alert. Activates the full alarm signal.

Manual distress alarm

 ( ) – Pressing the button activates the full alarm

signal.

Low  battery  alert

  ( )  –  Flashing  amber  LED  and  beep  every  five

seconds.

Thermal exposure alarm 1

 – Lower time/temperature threshold reached.

Activates a short repeating double-beep alarm tone and flashing red LEDs.

Press the right-hand button ( ) to silence the alarm.

Thermal exposure alarm 2

 – Higher time/temperature threshold reached.

Activates the full alarm signal.

Buddy-beacon

 – Blue LEDs pulsing at low frequency.

Full alarm signal

 – A high-pitched pulsating alarm signal accompanied by

alternating red and blue LEDs.

!

i

i

!

i

i

1

4110

1   Active LED

6   LED panel

2   Low battery LED

7   Manual alarm button

3   Right-hand button

8   RF communication point

4   Tally (option)

9   Left-hand button

5   Thermal sensor

3

4

1 2

6

7

5

8

9