background image

Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers 

with the latest medical inventions with an objective to promote good health and wellness 
all around the world. All the medical devices and health monitors provided by Dr Trust are 
supported  by  accurate,  latest  and  ground  breaking  technologies,  innovated  at  our 

headquarters  in  NY,  USA.  All  our  products  adhere  to  the  most  stringent  CE  and  FDA 
guidelines  and  are  strongly  recommended  by  doctors  and  health  practitioners.  Our 
products are designed in the utmost exemplary ways to ensure that their accuracy and 
convenience are unrivalled. The ease of their use and operation makes them even more 

suitable for users of all age groups.

Dr Trust strives to enhance the quality of lifestyle by providing with the most trusted and 

innovative health care and wellness products. Being a renowned global leader in health 

care products, Dr Trust ensures that our technically efficient team works dynamically and 

tirelessly to provide the best of the medical devices to our clients. The products that we 
have to offer are suitably designed for use at homes, laboratories and hospitals.

Our  ground  breaking  solutions  allow  you  to  monitor  your  health  in  the  easiest  ways 

possible. In today's era when all of our lives are too hassled to handle, it becomes a bit 

difficult to pay attention to our health. But it has now become easier with the coming of the 

monitoring devices which can be conveniently used at homes and even on the go. 

12. ABOUT US

SMART PORTABLE

ECG PEN

We bring to you a variety of best self medical devices, trusted and used by Doctors, 
medical professionals and home users all over the world.

Thank you for purchasing Dr. Trust Smart Portable ECG Pen. Please read the

instructions before use. 

1

26

Summary of Contents for ECG PEN

Page 1: ...e by providing with the most trusted and innovative health care and wellness products Being a renowned global leader in health care products Dr Trust ensures that our technically efficient team works dynamically and tirelessly to provide the best of the medical devices to our clients The products that we havetoofferaresuitablydesignedforuseathomes laboratoriesandhospitals Our ground breaking solut...

Page 2: ...ement 6 Taking Measurement 7 Result Display 8 iBP Monitor APP 3 3 4 5 7 8 13 14 9 Cleaning and Maintenance 10 Messages and Trouble Shooting tions 12 EMC Information 13 Customer Support 16 17 18 19 25 1 SYMBOL DEFINITIONS 2 GENERAL NOTES 1 ThisisanElectrocardiogram ECG devicethatprovidesreferentialdatathatcouldbetakeninto considerationbymedicalprofessionals 2 TheappliedpartisECG 3 Selfdiagnosisortr...

Page 3: ...Donotstore exposethedeviceinthefollowingenvironments Locationsexposedtodirect sunshine hightemperatureorhumidity heavydirt nearwateror e andunderhighelectro magnetic Storethedeviceinsafeplacetoavoidsmallpartsswallowedbychildrenunderanycircumstances Static electricity may cause damage to the electronic components to preventelectrostaticdamagetothe device grounding yourself to discharge the static e...

Page 4: ... Digits Display a Shows the sequence number of the measurement results stored in memory b Shows the 30 second count down during measurement 5 Time Shows date and time 6 Bluetooth Connection Displays the status of Bluetooth connection 5 PREPARATION BEFORE TAKING MEASUREMENT To charge your ECG Pen please follow the steps below 1 Remove the battery cover by inserting the tip of y er 2 Follow the posi...

Page 5: ...of each individualuser Ifitisnotpossibletotakestablemeasurementsusingagivenmeasurementmethod this could have a harmless cause such as the shape of the heart However the cause may also be an illness or disease Measurement method C offers maximum comfort but offers a much lower measurement stability than methodsAorB Presstheon offbuttonforaboutthreesecondstoturnthedeviceon Thedeviceshowsthefulldispl...

Page 6: ... against your chest until you hear or feel a click Important Do not exert excessive pressure on the electrodes with y Important Do not pr our skin Measurement method C left hand right hand approximately corresponds to lead 1 Place y wo upper electrodes on the device our left hand on the lower electrode Press the lower electrode until you hear or feel a click Important Do not pr our skin Please not...

Page 7: ...lding ECG Pen in the wrong direction 7 Result Display Normal Result Slow Heart Rate 60 bpm Fast Heart Rate 100 bpm Paused Heart beat pause 2 s Irregular Rhythm Disrupted Rhythm Abnormal Waveform Altered Waveform Please note that if the displayed heart rate is it indicates ECG signals are unstable or weak Pleaseretakethemeasurement Measurement Results The possible results are shown below 13 12 ...

Page 8: ...dGoogleplaystoresforandroidusers Downloading the app You can connect IBP monitor app with your Dr Trust ECG Pen devices using Bluetooth 4 0 It helps in providing real time display of ECG and blood pressure measurements The app also automatically stores recordsonsmart phoneortabletforfurtherdiagnosis QR code scanning Application Interface Measure Using the measure feature ECG and blood pressure can...

Page 9: ...e Shown Possible Cause Suggestion Measurement result shows t Rate Unstable or weak ECG signals Please retake the measurement following the manual s instruction Measurement result shows EE Failure analysis resulted from either low contact pressure or h i g h n o i s e l e v e l d u r i n g measurement Please retake the measurement following the manual s instruction Problem Possible Cause Suggestion...

Page 10: ...nitor APP Problems of data exchanging for tion If the device is discovered successfully there will be a blank on the box then click on the blank to manually link the device with APP and display the device ID 11 SPECIFICATIONS 12 EMC INFORMATION 19 18 ...

Page 11: ...21 20 ...

Page 12: ...bserved to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating theDr TrustECGPen Recommended separation distances between portable and mobile RF communications equipment and the Dr Trust ECG Pen The Dr Trust ECG Pen is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled T...

Page 13: ...umoutputpowerratingofthetransmitterinwatts W accordingto thetransmittermanufacturer NOTE1At80MHzand800MHz theseparationdistanceforthehigherfrequencyrangeapplies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorptionandr tionfromstructures objectsandpeople COPYRIGHT 2018 DR TRUST ALL RIGHTS RESERVED www drtrustusa com dr drtrustusa com drtrust ...

Reviews: