dr. Mercola Pure & Clear PC-AP2000 Owner'S Manual Download Page 6

Page 11

Page 10

Disassembly / Assembly

DISASSEMBLY:

You will need a #1 PHILLIPS SCREWDRIVER.

WARNING! Do not operate the unit unless the 

following are properly installed: PCO CELL, 

PURIFICATION PLATE, REAR FILTER ASSEMBLY 

(with all three pieces in place), and the REAR COVER.

CAUTION! The unit should be powered off and the 

POWER CORD should be disconnected whenever 

cleaning/disassembling/reassembling/servicing.

1. Turn the unit off. (See “CONTROLS”)

2.

Removing the Power Cord

(a) Unplug POWER CORD from wall outlet. 

(b) Remove POWER ADAPTER PLUG from rear 

of unit.

3. Clean the exterior of the unit if necessary. (See 

“CLEANING: UNIT EXTERIOR”)

4.

Removing the Rear Cover

:  

(a) Using your SCREWDRIVER, remove the REAR 

COVER SCREW from the REAR COVER (above 

the POWER CORD PORT). Place the REAR 

COVER SCREW where you will find it easily 

during reassembly.  

(b) Squeeze the tabs on both sides of the REAR 

COVER (where the grooves are) until they release 

and tilt the REAR COVER upwards until the top 

tab releases. Clean if necessary with compressed air 

or a damp cloth, then set the REAR COVER aside.

5.

Removing the Filter Assembly

(a) Remove BRASS THUMBSCREWS from the top 

corners of the FILTER ASSEMBLY. Place BRASS 

THUMBSCREWS where you will find them easily 

during reassembly. 

(b) Grasp the top of the FILTER ASSEMBLY and 

tilt the FILTER ASSEMBLY away from the unit. 

Clean if necessary (See “CLEANING: FILTER 

ASSEMBLY”) and set the FILTER ASSEMBLY 

aside.

6.  Removing the Purification Plate

(a) Grasp the PURIFICATION PLATE on the 

ceramic between the black arrows and gently pull 

the PURIFICATION PLATE out of the grooves 

on the sides. Clean if necessary (See “CLEANING: 

PURIFICATION PLATE”) and set the 

PURIFICATION PLATE aside.

7.

Removing the Pco Cell

(a) Locate the PCO CELL POWER 

CONNECTOR on the right of the rear of the unit 

almost halfway up (beside the PURIFICATION 

PLATE SLOT). Squeeze the tabs on the top 

and bottom of the PCO CELL POWER 

CONNECTOR and gently pull until free from the 

PCO CELL POWER CONNECTOR OUTLET. 

(b) Remove the THUMB NUTS from the SCREW 

POSTS on the right and left below the PCO CELL. 

Place THUMB NUTS where you will find them 

easily during reassembly. 

(c) Gently slide the PCO CELL out of the unit. 

Clean if necessary (See “CLEANING: PCO CELL”) 

and set the PCO Cell aside.

8. Clean the interior of the unit if necessary (See 

“CLEANING: UNIT INTERIOR”)

9.

Removing the Front Grille

(a) Locate the four FRONT GRILLE SCREWS in 

the four corners of the FRONT GRILLE. Using 

your SCREWDRIVER, carefully remove the four 

FRONT GRILLE SCREWS. Place the FRONT 

GRILLE SCREWS where you will find them easily 

during reassembly. 

(b) Remove the FRONT GRILLE carefully to ensure 

that the IONIZATION NEEDLE (in the top center 

of the front of the unit) is not damaged. Clean the 

FRONT GRILLE if necessary (using compressed 

air, vacuum cleaner, a damp cloth, or warm soapy 

water) and set the FRONT GRILLE aside. Clean 

the IONIZATION NEEDLE if necessary (See 

“CLEANING: IONIZATION NEEDLE”).

Disassembly / Assembly Cont.

Assembly

You will need a #1 PHILLIPS SCREWDRIVER.

WARNING! Do not operate the unit unless the 

following are properly installed: PCO CELL, 

PURIFICATION PLATE, REAR FILTER ASSEMBLY 

(with all three pieces in place), and the REAR COVER.

CAUTION! The unit should be powered off and the 

POWER CORD should be disconnected whenever 
cleaning/disassembling/reassembling/servicing.

1.  Installing the FRONT GRILLE

:  

(a) Gently put the FRONT GRILLE in place on the 

front of the unit, being careful not to damage the 

IONIZATION NEEDLE at the top center of the 

front of the unit. 

(b) Insert the four FRONT GRILLE SCREWS one 

at a time until they are in place, but not tight. After 

all four FRONT GRILLE SCREWS are in place 

tighten them carefully.

2.  Installing the PCO CELL

:  

(a) Gently slide the PCO CELL - tabs toward the 

rear of the unit - into place at the top of the rear of 

the unit. Ensure the SCREW POSTS slide into their 

holes in the tabs on the PCO CELL. 

(b) Screw the THUMB NUTS onto the SCREW 

POSTS until they are snug. 

(c) Align the PCO CELL POWER CONNECTOR 

to the PCO CELL POWER CONNECTOR 

OUTLET and insert gently until the tabs at the 

top and bottom of the PCO CELL POWER 

CONNECTOR snap into place, holding it in the 

PCO CELL POWER CONNECTOR OUTLET.

3.

Installing The PURIFICATION PLATE

(a) Holding the PURIFICATION PLATE by 

the ceramic between the black arrows, slowly 

insert the PURIFICATION PLATE into the 

PURIFICATION PLATE SLOT, ensuring that 

the PURIFICATION PLATE is sliding into the 

grooves on either side and the black arrows on the 

PURIFICATION PLATE are pointing towards the 

front of the unit. NOTE: About halfway in, the 

PURIFICATION PLATE will encounter resistance 

as the PURIFICATION PLATE CONNECTORS 

are parted. Continue sliding the PURIFICATION 

PLATE into the PURIFICATION PLATE 

SLOT until there is approximately one inch of 

the PURIFICATION PLATE remaining outside 

of the PURIFICATION PLATE SLOT and 

significant resistance is met. Be careful not to force 

the PURIFICATION PLATE further into the 

PURIFICATION PLATE SLOT as this could 

seriously damage your unit.

4.

Installing the FILTER ASSEMBLY

:  

(a) Hold the FILTER ASSEMBLY with the flat side 

facing the interior of the unit. Insert the bottom of 

the FILTER ASSEMBLY into the tabs on the rear of 

the unit and then seat the FILTER ASSEMBLY on 

the rear of the unit. 

(b) Screw the BRASS THUMBSCREWS into their 

holes at the top corners of the FILTER ASSEMBLY.

5.

Installing the REAR COVER

(a) Place the tab at the top of the REAR COVER 

into the hole at the top of the FILTER ASSEMBLY 

then lay the REAR COVER flat against the rear 

of the unit until the tabs on the sides of the REAR 

COVER click into place on the unit. 

(b) Carefully insert the REAR COVER SCREW 

into its hole on the REAR COVER (above the 

POWER CORD PORT) and tighten.

6.

Installing the POWER CORD

(a) Insert the POWER ADAPTER PLUG into the 

rear of the unit. 

(b) Ensure the POWER CORD is properly 

connected to the POWER ADAPTER. 

(b) Insert the POWER PLUG into a wall outlet.

7. Turn the unit ON. Ensure that the unit’s settings 

are adjusted to suit the environment. (See 

“OPERATIONS”)

Summary of Contents for Pure & Clear PC-AP2000

Page 1: ...s 5 Initial Setup Placement Settings 8 Operations 9 Maintenance 9 LCD Reminders 9 Disassembly Assembly 10 Cleaning 12 Troubleshooting 13 Consumer Information 14 Specifications 14 Warranty Information 14 Distributed by Mercola Health Resources LLC 3615 Exchange Avenue Aurora IL 60504 AIR PURIFIER Pure Clear ...

Page 2: ... unit near a heat source open flame or flammable combustable fluids WARNING Do not operate the unit unless the following are properly installed PCO CELL PURIFICATION PLATE REAR FILTER ASSEMBLY with all three pieces in place and the REAR COVER WARNING Eye damage may result from directly viewing the light produced by the lamp inside of this unit Eye damage occurs after 20 minutes of continuous expos...

Page 3: ...point Ionization The Pure Clear Air Purifier generates a continuous stream of millions of negative ions that circulate throughout the home These ions charge particles of dust dander bacteria and viruses causing them to attract other particles and clump together As more and more particles come together they become heavier making them easier to pull into the homes furnace filter or just fall to the ...

Page 4: ...ode Timer HIGH FT2 PURIFIER SETTING MUST NOT EXCEED SIZE OF AREA High Mode Purifier Warning Square Footage Indicator Fan Level Indicator High mode Indicator Purifier Capacity Indicator NORMAL Normal Mode Technology Indicator Fan Level Indicator Normal Mode Indicator Control Panel Power Button Fan Control Infrared Reciever Purifier Control Normal High Toggle Reminder Reset Button Away Mode Toggle C...

Page 5: ...oms and a laundry room The kitchen and three bedroom s doors remain open the majority of the time but the laundry room and den usually remain closed off from the rest of the house Together the laundry room and den have a combined area of 500 square feet The area of your environment would be 2000 square feet After you have established the placement of your unit and the area of the environment conne...

Page 6: ...ONIZATION NEEDLE Disassembly Assembly Cont Assembly You will need a 1 PHILLIPS SCREWDRIVER WARNING Do not operate the unit unless the following are properly installed PCO CELL PURIFICATION PLATE REAR FILTER ASSEMBLY with all three pieces in place and the REAR COVER CAUTION The unit should be powered off and the POWER CORD should be disconnected whenever cleaning disassembling reassembling servicin...

Page 7: ...EAR COVER CAUTION The unit should be powered off and the POWER CORD should be disconnected whenever cleaning disassembling reassembling servicing Unit Fails to Turn On 1 Verify that the POWER PLUG is plugged into an operational wall outlet 2 Ensure that the POWER CORD is properly connected to the POWER ADAPTER 3 Ensure that the POWER ADAPTER PLUG is fully seated in the receptacle on the back of th...

Page 8: ... period as the purifier Any damages or malfunctions caused by negligence abuse or use not in accordance with the Owner s Manual are not covered by this warranty Likewise any defects or damages caused by unauthorized service or the use of other than Genuine Pure Clear Air Purifier parts are not covered Mercola com at its option repair or replace a defective Air Purifier or part s for the Air Purifi...

Page 9: ...www GreenTechEnv com AIR PURIFIER Pure Clear Distributed by Mercola Health Resources LLC 3615 Exchange Ave Aurora IL 60504 www mercola com 847 252 4355 ...

Reviews: