DPtech DPX19000 Series Deep Service Switching Gateway
Installation Manual
Chapter 1 Product introudction
11
Note:
Flashcard is used to store the “Conboot” boot file.
Memory card is used to store system running data and also it can be data-cache when you forward
data packets.
CF card is used to store the software and configuration file of the device.
2. LED indicators
(
3
)
(
6
) (
10
)
(
14
)
(
18
)
(
20
)
(
19
)
(
23
)
Figure1-8 N-MPUA (N-MPUA) status LED
LED
Status
Description
(6)MPU
slot
status
LED(MPU2)
Off
Means no recognizable module inserted in the slot or system
installation isn’t finished.
Green(blink)
Means slot module is running and working normally.
Red
Means slot module is failure.
(10)
LPU
slot
status
LED(LPU4)
Off
Means no recognizable module inserted in the slot.
Green(blink)
Means slot module is running and working normally.
Red
Means slot module is failure.
(14)FUA
slot
status
LED(FUA4)
Off
Means no recognizable module inserted in the slot.
Green(blink)
Means slot module is running and working normally.
Red
Means slot module is failure.
(18)
PWR
status
LED
(
PWR3
)
Green
Means power supply is working normally.
Red
Means power supply is not working normally.
(19)ACT status LED
(
ACT
)
Green
Means the main control board is in active status.
Off
Means the main control board is in backup status or device isn’t