background image

4

5

CLEANING GUIDE

When mounting the 4088 on a performer,

care should be taken to avoid sweat from

running directly into the microphone. If the

microphone gets filled up with water or sweat

it will possibly turn deaf while the water is

captured inside the microphone, behind the

fixed protection grid.

Care of the microphone element

The microphone diaphragm is protected

inside the microphone housing and there is

no access to the diaphragm. It is well pro-

tected from dust build-up and no attempt

should be made to remove the protection

grids to clean the diaphragm. The protec-

tion grids are not removable, therefore no

attempt should be made to clean the grid

surface and extreme care should be taken

not to clog the grids with make-up or other

such substances.

If water or sweat has entered the micro-

phone element, remove it by shaking the

microphone gently. When it is left to dry out

it will recover to its original specifications.

Drying out the 4088 between exposures to

humidity will also help to extend its lifetime.

Do not use any kind of cleaning fluid. Use of

ultra-sonic baths must be avoided. Avoid all

kinds of spray or fluids, which contain

chemical components to remove static

electricity on or close to the microphone as

this could cause damage to the electret layer.

Cleaning the microphone cable

Residue from tape, glue or make-up on the

cable must be removed after use. Leaving

these substances on the cable over longer

periods of time may etch into the cable

jacket and will make the cable more suscep-

tible to breaks. The cable can easily be

cleaned using organic oil (e.g. olive oil) or

lukewarm, distilled water. Do not bend the

cable or rub it harshly since this may stress

the inner cores of the cable and cause

them to break over time.

INTRODUC TION

To ensure optimal performance of your

4088, please follow the simple instructions

of care, maintenance, and mounting below.

The Cardioid Headband 4088 from DPA is

designed to be very resistant to humidity,

moisture and sweat. Highly resistant mate-

rials are used in construction of the micro-

phones, to avoid damage by hostile fluids. 

In any case, it is still a good idea to keep the

4088 microphone away from any kind of

cleaning, unnecessary exposure to water

and cleaning fluids, and to keep the micro-

phone element dry at all times.

PLACEMENT

In general, to ensure the optimal sound of

the 4088, it must be mounted at about 

2-3 cm (1 inch) from the corner of the

mouth. Correct placement ensures that

you avoid air noises from the nose and

mouth from being captured by the micro-

phone. Avoid any contact with beards or

moustaches. Please note that the 4088 is

not designed for placement directly in front

of the mouth. The sound timbre and pressure

is as good at the corner of the mouth as it

is directly in front of it. See the pictures below.

Keep dry

Correct placement of microphone 
at corner of mouth.

Correct placement of microphone at
corner of mouth

Sweat stopper to hinder sweat reaching
the capsule by running down the boom.

Sweat stopper

Summary of Contents for 4088

Page 1: ...USER S MANUAL Type 4088 Cardioid Headband 4088 ...

Page 2: ...ONTENTS Introduction 4 Placement 4 Cleaning Guide 5 Correct use of the Cardioid Headband 4088 6 Specifications 12 Accessories Available 14 Service Repair 16 Warranty 16 CE Standard 16 Type 4088 Cardioid Headband 4088 ...

Page 3: ...ubstances on the cable over longer periods of time may etch into the cable jacket and will make the cable more suscep tible to breaks The cable can easily be cleaned using organic oil e g olive oil or lukewarm distilled water Do not bend the cable or rub it harshly since this may stress the inner cores of the cable and cause them to break over time INTRODUCTION To ensure optimal performance of you...

Page 4: ... nector in this instance Contact the nearest DPA Microphones representa tive for maintenance advice or assistance Correct use of adapters and MicroDot connectors To provide users with safe and compact mounting of connectors all Miniature Microphones from DPA are fitted with the MicroDot connector as standard A broad range of connection adapters is offered as optional accessories for most VHF and U...

Page 5: ...ssible tensile strength in the design In case of failure MicroDot spare parts tool and assembly tool and assembly guide can be acquired Various wireless systems require the use of electronic components inside the adapter to optimise the signal level the DC offset filtering and powering of the built in micro phone preamplifier Using the adapters from DPA Microphones ensures the correct electronic c...

Page 6: ... inwards with your thumbs The ear hooks are also adjustable If you want the position of the microphone boom to be altered at this point adjustments are still possible simply by drawing the boom while holding a firm grip with the other hand on the headband Do not bend by holding on to the capsule itself Instead bend the wire boom making a smooth curve with your thumb to best fit the profile of the ...

Page 7: ...level ITU R BS 468 4 Typ 38dB max 40dB Max SPL 144 dB SPL peak before clipping Total Harmonic Distortion 123dB SPL peak 1 THD 120dB SPL RMS sine 1 THD Polarity Positive going sound pressure produces positive going voltage on MicroDot pin Operating temperature range 10 to 45 C 14 to 113 F Output impedance 30 40 Ohm Cable drive capability Up to 300m 984ft Microphone length 11mm 0 5in Microphone diam...

Page 8: ...063 DAD6004 Audio Ltd Tx 2000 Tx 2020 DAD6006 Beyerdynamic TS42 TS85 TS190 TS900 DAD6007 AKG PT 300 DAD6008 Sony WRT820 WRT860 DAD6009 Samson CT 2 TX 3 UT4 UT5 UT6 DAD6010 Shure U1 UT1 SC1 TOA WM4300 DAD6011 Vega T 66 T 677 Shure U1L DAD6012 Lectrosonics M185 DAD6013 Micron TX501 x TX502 x DAD6014 Pastega TMA16 TMU20 2 wire preset DAD6015 Vega T 37 DAD6017 AKG PT 40 60 80 81 Samson UT1L VT2L DAD60...

Page 9: ...5 48 14 28 28 FAX 45 48 14 27 00 You can also get in touch with DPA Microphones at info dpamicrophones com or visit our website at www dpamicrophones com WARRANTY All products from DPA Microphones are covered by a two year limited warranty on both mechanical functionality and docu mented specifications as long as the items are not mistreated abused or modified in any way In case of a warranty clai...

Page 10: ...DPA Microphones A S Gydevang 42 44 DK 3450 Alleroed Denmark Tel 45 4814 2828 Fax 45 4814 2700 info dpamicrophones com www dpamicrophones com DPI 4088 ...

Reviews: