background image

1

E2330PA

E2330PM/PMC

120 1 Phase 60Hz

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DANGER

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

CAREFULLY FOLLOW THESE INSTRUCTIONS

TABLE OF CONTENTS

DESCRIPTION

    

 PAGE

Installation and maintenance manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 2

Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 3

Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 4

Distances to respect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 5

Model option description and front panel symbol signification . . . . . . . .

 7

Operation of unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 8

Before calling for service - Answers to most frequent questions . . . . . . .

 9

Maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
For more information, please call our office: . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensions E2330, PA, PM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Dimensions E2330PMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Component parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

Electric schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

E2330_F.DOC

REV. 2003-09-25

Summary of Contents for E2330PA

Page 1: ...nance manual 2 Construction 3 Shipping 3 Warnings 4 Distances to respect 5 Installation 5 Model option description and front panel symbol signification 7 Operation of unit 8 Before calling for service Answers to most frequent questions 9 Maintenance and cleaning 9 For more information please call our office 10 Dimensions E2330 PA PM 12 Dimensions E2330PMC 14 Component parts 16 Electric schematic 2...

Page 2: ...es the serial number model number number of phase amperage voltage and frequency Drawings electrical diagram and replacement part numbers are included in this manual The electrical diagram is affixed in the control panel located on the top of the proofer ATTENTION DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by known organizations T...

Page 3: ...efore shipment The freight company assumes full responsibility concerning the delivery in good condition of the equipment in accepting to transport it IMPORTANT RECEPTION OF THE MERCHANDISE Take care to verify that the received equipment is not damaged before signing the delivery receipt If a damage or a lost part is noticed write it clearly on the receipt If it is noticed after carrier left conta...

Page 4: ...ce must be done by specialized technicians Contact a certified electrician and plumber for set up The proofer must be connected to the utility and electrically grounded in conformity to the effective local regulations If these are not established the oven must be connected according to the Canadian Electrical Code CSA C22 1 XX or National Electrical Code NFPA 70 XX Refer to last edition year for X...

Page 5: ...it 1 To the electrician Electrical supply installation must be in accordance with the electrical rating on the nameplate 2 To the plumber Connect the steam system 1 4 pipe to the water distribution network Warning Do not adjust the needle valves it has been done at the factory 3 To the plumber This equipment is to be installed to comply with the applicable federal state or local plumbing codes Con...

Page 6: ...110 F Automatic water entry 1 4 pipe 120 1 60 1500 WATTS 12 5 AMPS E 2330PM PMC Proofer only 50 F TO 110 F Manualy fill 120 1 60 1500 WATTS 12 5 AMPS front panel symbol signification breaker temperature control main power switch humidity control fill water pan ...

Page 7: ...leted turn the switch OFF 6 If you have the optional manual water fill when the water tank pilot light on front panel stay on the water tank is empty Fill the water tank with distillate water When the proofer is not in operation open the doors to let out the humidity and then prevent mold P S The doors should not be opened unnecessarily to conserve the heat and humidity in the proofer Every day cl...

Page 8: ...ce heat Make sure that the thermostat is adjusted to the desired temperature over ambiant temperature and the pilot light will go on The blower runs but the unit does not produce steam Make sure that the humidity control is set at about 5 Check if the water valve of the building is open and if water goes into the proofer unit located on the top of the unit Check the water needle valve on top of th...

Page 9: ...th a stainless steel polish We recommend and sell Stapol Stainless steel polish KEM Mfg Canada Part number NES201 Clean the water system on the top of the unit Twice a year clean the water pan and the immersion element the water tank if is manual fill unit and the screen filter SEE NEXT PAGE Is very important to use distillate water whit the manual water fill option and a high quality water filter...

Page 10: ...on please contact our office DOYON EQUIPMENT INC 1255 rue Principale Linière Qc Canada G0M 1J0 Tel 1 418 685 3431 Canada 1 800 463 1636 U S 1 800 463 4273 FAX 1 418 685 3948 Internet www doyon qc ca E Mail doyon doyon qc ca ...

Page 11: ...11 E2330PA PM DIMENSIONS ...

Page 12: ...12 ...

Page 13: ...13 E2330PMC DIMENSIONS ...

Page 14: ...14 ...

Page 15: ...15 E2330 COMPONENT PARTS ...

Page 16: ...16 ...

Page 17: ...40 INFINITY SWITCH KNOB 1 4 ELI550 MAIN SWITCH SELECTOR 1 AND ELI555 CONTACT BLOCK 1NO 1 AND ELI556 ON OFF PLATE 1 5 ELB096 5A BREAKER 1 6 P2031E DOOR 31 3 8 x 20 1 2 FOR E2330 2 7 QUP500 LATCH 2 8 QUP320 DOOR HINGE 4 9 PAR800 SWIVEL CASTER 2 AND PAR850 SWIVEL CASTER WITH BRAKE 2 OR PAR400 WHEEL 2 1 2 INCH FOR PMC MODEL ONLY 2 AND PAR450 WHEEL 2 1 2 INCH WITH LOCK FOR PMC MODEL ONLY 2 Model E2330 ...

Page 18: ...18 ...

Page 19: ...20V 1 6 ELM735 SOLID STATE TIMER ICM FOR CH460 JAOP3 G FC2 G AND E233 2 7 ELM734 MOTOR BLOWER 80 DFM 1 8 ELE126 FORMED ELEMENT 120V 1000W 1 9 ELE164 IMMERSION ELEMENT 120V 500W 1 10 QUF350 ELECTRIC FLOAT 1 11 ELF030 PLUG 2 POLES 3 WIRES 125V 15A 1 12 ELS880 SOLENOID VALVE 110 120V 50 60Hz 1 13 ELV590 NEEDLE VALVE 1 14 PLF100 WATER FILTER 1 15 ELT504 THERMODISK 145 F OPTIONEL 1 Model E2330 View TOP...

Page 20: ...20 E2330 ELECTRIC SCHEMATIC 120 VOLTS ...

Page 21: ...PAN OR CHECK WATER LINE INLET LIGHT WATER PAN C1 EACH C1 LIGHT PILOT ON OFF LIGHT PILOT N L1 P1 LIQUID LEVEL L2 L1 P H2 H1 INFINIT SWITCH 500 W HUMIDITY 1KW AT 12 5A HEAT 1 4 8 5 P1 7 2 PROOFER VALVE R1 8 7 R1 5 3 E2330 120 VOLTS 1PH 60HZ 23 08 05 M FAUCHER 2 NONE STANDARD E2230 1 1 120 12 5A 12 5A 1 5KW 120 17A 17A 2KW TOTAL POWER 60HZ ...

Page 22: ...ible for having the equipment properly installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the period of one year from date of purchase Doyon Equipment Inc hereby guarantees to replace without charge F O B Linière Quebec Canada such part or parts Doyon Equipment Inc will pay the reasonable labor ...

Reviews: