(continued)
Problem
Soot deposit on ther-
mocouple
Clean the thermocouple with a cloth.
Thermocouple faulty
Replace the thermocouple (*).
No spark
Spark but no ignition
When ignition button is released, pilot flame goes out
Main burner does not ignite
Whistling between high and low setting
Disrupted flame effect
Gas smell
Smell of combustion gases in room
Appliance goes out
Remote control does not work
possible cause
possible solution
(*) = have installer carry out this action
Electromagnetic valve faulty
Replace the control block (*).
Blocked pipes or nozzles
Blow through the parts and clean them (*).
Burr on nozzle
Remove the burr (*).
Dirty burner
Clean the burner, check the placement of the logs,
remove any coal from the burner openings (*).
Gas leak
Close the main valve, find the gas leak and repair the leak
(*).
Blocked smoke exhaust
duct or air supply ducts
Check the ducts and clean them (*).
Appliance is leaking air
Check the door seals and appliance joints (*).
Dust on combustion cham-
ber
Clean the combustion chamber.
Empty batteries
Replace the batteries.
Wiring to gas block
Trace any bad contact point and repair it.
Faulty transmitter or
receiver
Replace the remote control.